HDMI encoder with IP output mhi430  

1. Product description

HDMI encoder with IP output (in text - module) designed to encode in H.264 standard and broadcast in multicast on an 

IP network the services (TV programs) issued from HDMI input. The IP streams can be viewed using an IPTV set-top box 

or a software video player.

Modules are intended for indoor use only. 

2. Characteristics

Input

: Three HDMI inputs. 

Output

: Three IP-encapsulated services (TV programs), encoded in H.264 standard, with individual multicast addresses. 

•  Generating of DVB tables.

•  UDP & RTP transmission protocols.

•  Web interface for configuration and setting.

•  SNMP agent for monitoring and alarms.

•  SAP & SDP protocols that facilitate automatic service selection on the user's STB and provide information to external 

servers.

•  PID configuration.

•  PSI/SI configuration.

•  PAT, PMT and SDT table generation.

•  Configurable QoS marking.

•  Configurable Time To Live.

3. Safety instructions

Installation of the module must be done according IEC60728-11 and national safety standards. 

Any repairs must be made by qualified personnel.

Do not expose this module to moisture or splashing water and make sure no objects filled with liquids, such as vases, 

are placed near or on the unit.

Avoid placing the module next to heat sources such as central heating components or in areas of high humidity.

Keep the module away from naked flames.

If the module has been kept in cold conditions for a long time, bringing it into a warm environment may cause condensation, 

so allow it to warm up for no less than 2 hours before plugging into the mains.

Ventilation should not be impeded by covering the module, such as newspapers, table-cloths, curtains etc.

Mount the module in a vertical position only. If installing in a 19” rack system additional forced air cooling fans may be 

required (see table "

Technical specifications

" - operating temperature range).

Always allow 10 cm of free space from the top, front and bottom of the unit to enable any heat to be dissipated.

Draugystes str. 22, LT-51256 Kaunas, Lithuania, tel.: +370 37 - 31 34 44, fax: +370 37 - 31 35 55 

E-mail: 

[email protected]

,

 http://www.terraelectronics.com

Channel processing equipment

  This product complies with the relevant clauses of the European Directive 2002/96/EC. The unit must be recycled    

 

 

  or discarded according to applicable local and national regulations.

   Equipment intended for indoor usage only.
  TERRA  confirms,  that  this  product  is  in  accordance  to  following  norms  of  EU:  EMC  norm  EN50083-2,  safety  norm  EN60065,  

 

RoHS norm EN50581.

   TERRA confirms, that this product is in accordance with Custom Union Technical Regulations: “Electromagnetic compatibility of technical  

 

equipment“ CU TR 020/2011, “On safety of low-voltage equipment“ CU TR 004/2011.

Vers. 1.02

Summary of Contents for mhi430

Page 1: ...as central heating components or in areas of high humidity Keep the module away from naked flames If the module has been kept in cold conditions for a long time bringing it into a warm environment may cause condensation so allow it to warm up for no less than 2 hours before plugging into the mains Ventilation should not be impeded by covering the module such as newspapers table cloths curtains etc...

Page 2: ...o set the default IP address of control over Ethernet interface Administrator password will be changed to the default value as well 8 Power distribution bus connector 9 12 V DC powering input Screw terminal 10 TS IP OUT streaming Ethernet interface RJ45 socket 11 ACTIVITY yellow indicator of the streaming Ethernet interface 12 LINK green indicator of the Ethernet interface 4 External view 6 MOUNTI...

Page 3: ...ged To restore IP address and system password to system defaults see RESET button at section 3 pos 7 Several seconds can take to restore all parameters so be patient 7 6 7 Restart the device Device will be restarted after confirmation to do it This is an alternative to pressing a RESET button when the device is operating 7 6 8 Date Time System time can be configured manually or taken from NTP serv...

Page 4: ...creen you will see a main menu tabs 1 Using it you can switch between the different configuration menus The tab highlighted in yellow shows which menu is active at a given moment The System menu tab contains several submenu Also common elements for all screens is module title 2 and login information strings 3 The module title can be changed after pressing the Change button in the Device informatio...

Page 5: ...ID of PMT 7 5 2 SNMP settings table The description of the SNMP settings table rows Enable TRAP SNMP traps are alerts generated by agents on a managed device Check this box to enable TRAP generation The streamer generates traps when the diagnostic message occurs Trap community Read community community name acts as a password that is shared by multiple SNMP agents and one or more SNMP managers The ...

Page 6: ...ty video 3 Low priority video 4 Video and voice 5 Best effort best effort made to correctly deliver the video data and the associated audio data Count of output streams count of output streams displayed in the Output streams table bellow Can be selected from one to twenty five After updating ot the FR input parameters this count is automatically set to input stream count value Send IGMP query mess...

Reviews: