8

Figure 10. Time settings screen

9.5 SNMP settings

This menu tab contains the SNMP configuration table (see Figure 11).

Figure 11. SNMP configuration

Description of the "SNMP configuration" table rows:

"Read Community": community name string that is required to access the SNMP agent Read-Only parameters.

"Write Community": community name string that is required to access or modify the SNMP agent Read-Write parameters.

"Enable TRAP": SNMP traps are alerts generated by agent. Check this box to enable traps generation. The module 

generates traps when the diagnostic alarm events occur.

"TRAP Community": is the community string used for generating the agent traps.

"Host IP #1","Host IP #2": IP addresses of hosts with SNMP managers, where traps will be sent.

“Download MIB file”: press this link to download the SNMP MIB file of the device. Save the archive on your computer and 

extract the archive content. Extracted MIB files are ready to use with SNMP manager software.

NOTE

: please read the user guide of SNMP manager software before using SNMP.

Press “Update” button to change SNMP agent settings.

9.6 System menu

This menu tab contains the following submenu items: "Event logs", "Export parameters", "Import parameters", "Firmware 

upgrade", "User management", "Restore defaults", "Reset the device", "Language".

9.6.1 Event logs

Move the cursor on the “System menu” dropdown list and then click on the "Event logs" option. The event logs screen 

will appear.

Summary of Contents for OAD514

Page 1: ...by a skilled personnel Do not connect the 12 V power supply unit into the mains socket until all cables of amplifier have been correctly connected The mains socket must be easily accessible Disconnect the amplifier power supply by removing the power supply cable from the mains socket Do not expose this device to moisture or water splashes make sure no liquid filled objects e g vases are placed nea...

Page 2: ...uts of the device Never leave equipment with radiating bare fibers accessible always cap the connectors 5 Cleaning of optical connectors The fiber ends may be damaged if contaminated connectors are inserted The warranty does not cover some types of damage made by the customer The standard optical connector for optical amplifier is FC APC During the operation each fiber connector may be contaminate...

Page 3: ...amplifier optical input FC APC socket 15 functional grounding clamp 7 Installation instructions Read the safety instruction first All settings can be changed using Web browser and Ethernet interface Disconnect the power supply unit from the mains before making any fiber optic cables connections Mount the module on DIN RAIL or individual holder Connect all necessary fiber optic powering and control...

Page 4: ...IN rail 8 MOUNTING The module or mounting bracket must be fixed with steel screws Ø 3 5 4 mm The screws are not included in a package Mounting on a wall by screws Mounting on a bracket supplied Perpendicular to the wall Parallel to the wall Figure 2 Mounting of the amplifier 1 2 ...

Page 5: ... use 192 168 1 10 since this is the IP address of the module to be configured To start the configuration of the module open your Web browser and type in the following direction http 192 168 1 10 The login prompt will appear on a screen see Figure 6 Figure 6 Login prompt Access to the Web interface is protected by user name and password The default user name and password is admin Enter the user nam...

Page 6: ... number of the device Title changeable device title Software version module software version number Hardware version module hardware version number IP IP address of the Ethernet interface System time current system time Up time time passed from last power up or restart of the module Common status table The following module parameters are displayed at real time Supply voltage module power voltage i...

Page 7: ... the physical address of the module Ethernet network card is displayed automatically IP Address enter the IP address that you wish to assign to the module This address must fall within the range of local network addresses Subnet mask enter the local network mask Gateway enter the IP address of the gateway This information is required only if you want to access the module from outside of your local...

Page 8: ...nity string used for generating the agent traps Host IP 1 Host IP 2 IP addresses of hosts with SNMP managers where traps will be sent Download MIB file press this link to download the SNMP MIB file of the device Save the archive on your computer and extract the archive content Extracted MIB files are ready to use with SNMP manager software NOTE please read the user guide of SNMP manager software b...

Page 9: ...parameters window is displayed see Figure 13 Figure 13 Import parameters window Click on Click to select file and select the file containing configuration data that you wish to restore on the module Once you have selected the file click on the Upload button at the bottom of screen When the import process is finished a notification window will be displayed 9 6 4 Firmware upgrade If you wish to upda...

Page 10: ...he user settings User role Admin enables the user to change all module settings and manage other users Limited user role User enables the password change function only It is forbidden to modify the module settings for limited user Press the Remove button to remove user from the list NOTE By giving your personal password or user access account for another person you take full responsibility for all...

Page 11: ...RE CLASS 3R LASER PRODUCT Wave length 1270 1610 nm IEC60825 1 This product complies with the relevant clauses of the European Directive 2002 96 EC The unit must be recycled or discarded according to applicable local and national regulations Equipment intended for indoor usage only Functional earthing Connect to the main potential equalization This product is in accordance to following norms of EU ...

Reviews: