4. Safety of laser product

Optical amplifier module contains laser diode source. This device is rated under IEC60825-1

 

“Safety of Laser Products”, 

Part 1: Equipment classification and requirements as CLASS 3R

 

laser product

.

When operating the equipment note the following:
Most fiber optic laser wavelengths are totally invisible to the eye and will cause permanent eye damage. 
Never look into the end of a fiber on a powered device through  a magnifying device (microscope, eye loupe, magnifying 

glass, etc.). Before using such devices always double check that power is disconnected or, if possible, completely disconnect 
the unit from any power source.

To verify the light output always use an instrument, such as an optical power meter.
Operate only with the proper optical fiber installed in the optical output connectors.
Whenever the optical connectors are empty the device should be turned off.
Before applying power always connect a fiber to the outputs of the device.
Never leave equipment with radiating bare fibers accessible - always cap the connectors.

5. Cleaning of optical connectors

The fiber ends may be damaged if  contaminated connectors are inserted. The warranty does not cover some types of 

damage, made by the customer. The standard optical connector for optical amplifier is FC/APC. 

During the operation each fiber connector may be contaminated by dust or dirt. Even tiny particles of dust will affect the 

transmission quality. Dusty fiber optic connector will contaminate other connected optic parts. If optical reception power and 
output level of the receiver decrease, active fiber connection should be cleaned and maintained. 

Always clean all the fiber optic connectors before setting. 
Reel cleaners or prepackaged lint free wipes or swabs with alcohol are the most convenient means of cleaning optical 

connectors.

Fiber connectors should never be left uncovered.
Do not exceed the minimum bending radius when connecting cable to the system.

6. External view

Laser
On

Status

DC 12V

-

  + 

1

2

3

4

7

6

5

8

9

1

4

1

5

10

11

12

13

Laser
On

Status

DC 12V

-

  + 

TERRA

Figure 1. External view of the amplifier

Summary of Contents for OAD514

Page 1: ...by a skilled personnel Do not connect the 12 V power supply unit into the mains socket until all cables of amplifier have been correctly connected The mains socket must be easily accessible Disconnect the amplifier power supply by removing the power supply cable from the mains socket Do not expose this device to moisture or water splashes make sure no liquid filled objects e g vases are placed nea...

Page 2: ...uts of the device Never leave equipment with radiating bare fibers accessible always cap the connectors 5 Cleaning of optical connectors The fiber ends may be damaged if contaminated connectors are inserted The warranty does not cover some types of damage made by the customer The standard optical connector for optical amplifier is FC APC During the operation each fiber connector may be contaminate...

Page 3: ...amplifier optical input FC APC socket 15 functional grounding clamp 7 Installation instructions Read the safety instruction first All settings can be changed using Web browser and Ethernet interface Disconnect the power supply unit from the mains before making any fiber optic cables connections Mount the module on DIN RAIL or individual holder Connect all necessary fiber optic powering and control...

Page 4: ...IN rail 8 MOUNTING The module or mounting bracket must be fixed with steel screws Ø 3 5 4 mm The screws are not included in a package Mounting on a wall by screws Mounting on a bracket supplied Perpendicular to the wall Parallel to the wall Figure 2 Mounting of the amplifier 1 2 ...

Page 5: ... use 192 168 1 10 since this is the IP address of the module to be configured To start the configuration of the module open your Web browser and type in the following direction http 192 168 1 10 The login prompt will appear on a screen see Figure 6 Figure 6 Login prompt Access to the Web interface is protected by user name and password The default user name and password is admin Enter the user nam...

Page 6: ... number of the device Title changeable device title Software version module software version number Hardware version module hardware version number IP IP address of the Ethernet interface System time current system time Up time time passed from last power up or restart of the module Common status table The following module parameters are displayed at real time Supply voltage module power voltage i...

Page 7: ... the physical address of the module Ethernet network card is displayed automatically IP Address enter the IP address that you wish to assign to the module This address must fall within the range of local network addresses Subnet mask enter the local network mask Gateway enter the IP address of the gateway This information is required only if you want to access the module from outside of your local...

Page 8: ...nity string used for generating the agent traps Host IP 1 Host IP 2 IP addresses of hosts with SNMP managers where traps will be sent Download MIB file press this link to download the SNMP MIB file of the device Save the archive on your computer and extract the archive content Extracted MIB files are ready to use with SNMP manager software NOTE please read the user guide of SNMP manager software b...

Page 9: ...parameters window is displayed see Figure 13 Figure 13 Import parameters window Click on Click to select file and select the file containing configuration data that you wish to restore on the module Once you have selected the file click on the Upload button at the bottom of screen When the import process is finished a notification window will be displayed 9 6 4 Firmware upgrade If you wish to upda...

Page 10: ...he user settings User role Admin enables the user to change all module settings and manage other users Limited user role User enables the password change function only It is forbidden to modify the module settings for limited user Press the Remove button to remove user from the list NOTE By giving your personal password or user access account for another person you take full responsibility for all...

Page 11: ...RE CLASS 3R LASER PRODUCT Wave length 1270 1610 nm IEC60825 1 This product complies with the relevant clauses of the European Directive 2002 96 EC The unit must be recycled or discarded according to applicable local and national regulations Equipment intended for indoor usage only Functional earthing Connect to the main potential equalization This product is in accordance to following norms of EU ...

Reviews: