Type
Width B (mm)
Height H (mm)
Depth L (mm)
B 14
610
1450
775
B 19
610
1450
825
B 23
640
1545
905
B 32
750
1545
905
B 42
790
1595
960
B 52
790
1595
1005
1.1
Technical Data Chart
Boiler type TOBY B
14
19
23
32
42
52
Total power
13.1 KW
18,5 KW
22,1 KW
31,1 KW
41,1 KW
51,2 KW
Power transmitted to the cen-
tral heating system
3.6-13.1
KW
4.8 - 18.5
KW
6.3 - 22.1
KW
9,6 - 31,1
KW
9,6 - 41,1
KW
9,6 - 51,2
KW
Min power pellet consump-
tion
min 0.86
kg/h
min 1.14
kg/h
min
1.5
kg/h
min
2,3
kg/h
min
2,5
kg/h
2,83 kg/h
Max power pellet consump-
tion
max
3.1
kg/h
max
4.4
kg/h
max
5.2
kg/h
max
7,4
kg/h
max
9,7
kg/h
12,1 kg/h
Width (mm)
610
610
640
740
790
790
Height (mm)
1450
1450
1545
1545
1595
1595
Depth (mm)
775
825
905
905
960
1005
Flue gas height (mm)
130
130
130
130
130
130
Boiler total weight
225 kg
245 kg
285 kg
315 kg
375 kg
405 kg
Pellet magazine capacity
80 kg
90 kg
100 kg
125 kg
145 kg
160 kg
Flow/Return (inch)
1"
1"
1"
1"
5/4"
5/4"
Filling Tap (inch)
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
Flue gas diameter ((
Φ
))
80 mm
80 mm
80 mm
80 mm
80 mm
80mm
Air inlet diameter ((
Φ
))
50 mm
50 mm
50 mm
50 mm
50 mm
50mm
Exit flue gas temperature at
total power
160
◦
C
160
◦
C
160
◦
C
160
◦
C
160
◦
C
160
◦
C
Necessary draught
10 Pa
10 Pa
10 Pa
10 Pa
11 Pa
12 Pa
Water volume
33 lit
44 lit
58 lit
78 lit
88 lit
98 lit
Electrical network connection
220 V 50
Hz
220 V 50
Hz
220 V 50
Hz
220 V 50
Hz
220 V 50
Hz
220 V 50
Hz
Electric energy consumption
during start-up
400 W
400 W
400 W
400 W
400 W
400 W
Energy consumption in oper-
ation
100 W
100 W
100 W
100 W
100 W
100 W
Efficiency
90 %
90 %
90 %
90 %
90 %
90 %
Boiler class
5
5
5
5
5
5
1.2
On Product
•
Hereby we thank you for purchasing TOBY B boiler. TOBY represents one of the most sophisti-
cated solutions for automatic combustion of wood pellets to be found on the market. It is completely
adapted to burn wood pellet as a primary fuel, achieving maximum efficiency level up to 92 % and
a very low exit temperature for flue gases (below 160
◦
C). Emission levels of this boiler fulfill the
most rigorous norms of European countries.
Main features include:
1. New burner (patented design!) with primary and secondary air-flow to ensure best combustion
results and highest efficiency
3