Nominal power* TKK3 max (KW)
100
120
150
200
250
300
Max power coal* (KW)
100
120
150
200
250
300
Max power wood* (KW)
87
103,5
129
169,5
210
262,5
Power range coal* (KW)
80-110
100-
130
130-
180
180-
240
220-
290
270-
350
Necessary draught (mbar)
0.29
0.3
0.35
0.41
0.45
0.5
Water content (l)
170
230
290
320
350
430
Output gas temperature at nominal power (
◦
C)
250
250
250
250
250
250
Temp. regulation range (solid fuel) (
◦
C)
60-90
60-90
60-90
60-90
60-90
60-90
Minimum temp. return line (solid fuel) (
◦
C)
60
60
60
60
60
60
Efficiency
76,7%
81,8%
81,6%
81,8%
81,9%
79,2%
Boiler class
3
3
3
3
3
3
Required chimney height** (m)
9-10
10-11
11-12
11-12
12-13
15-17
Required chimney inner diameter** (mm)
250
250
300
350
350
350
* Values given for coal with caloric value 18000 KJ/kg and in the field below for firewood with caloric
value of 15000 KJ/kg. ** Please consult chimney producer manual for detailed information on chimney.
1.3
Maximum Wood Log Size
When using firewood, please note that this is the maximum log length you can put into the boiler.
Boiler type TKK3 max (KW)
Max wood log length (mm)
Heating chamber depth (mm)
100
800
812
120
900
912
150
900
912
200
1000
1015
250
1200
1215
300
1200
1215
1.4
On Product
•
This boiler is aimed for manual feed of solid fuel (brown coal, firewood, brickets or biomass with
declared caloric value greater than 15000 KJ/kg).
•
Boiler is constructed by welding steel plates (4-6 mm thickness). Manufacturing process was per-
formed by strict following the guidelines of the corresponding European norms EN 303/5 and ISO
9001. Only certified materials are built in as required by EN 10025, EN 10028-2, EN 10120 and EN
10088-2.
•
Efficiency of the boiler is higher than 77% thanks to its three pass construction.
•
Upper and lower door are covered by refractory insulation material based on VERMICULITE
mineral - large amount of heat is kept in the boiler as a consequence.
•
Boiler has capacious upper door to facilitate manual feeding of the solid fuel.
•
Combustion control is done by draught regulator (to be ordered separately and mounted on boiler
before use).
•
Maximum working pressure is 4 bar. Water control test is done on 6 bar.
•
Boiler is delivered with cleaning kit.
3