ver.2
44
Note: the automation of the boiler includes an environmental wireless
chronothermostat, by the serial connection to the control thermostat.
Functions of the control elements of the boiler:
1. thermomanometer – indicates the temperature and hydraulic pressure in the boiler;
2. maximum control thermostat– connects / disconnects the air fan at the adjusted temperature
according to the temperature of the water in the boiler. The temperature can be adjusted up to 90
°C, but the recommended value is of 70 - 90 °C.
3. led general switch - used for the total disconnection of the power.
4
.
safety thermostat – stops the pellets burner at over-temperatures or when the first thermostat is
faulty – manual resetting. To reset, unscrew the protection cover and push the unblocking button
of the thermostat on the control panel.
5. wire fuse 6A – for the protection of the control panel.
4.4. Fuel feeding and re-feeding
4.4.1. Feeding and re-feeding for wood operation
Fuel feeding is manually executed, using any type of solid fuel (wood, wood waste, wood
powder briquette, coals). We recommend a maximum humidity of 35% for the wood.
The drier is the wood, the lesser is the wood chipping degree .
Feeding the boiler with wood takes into account the outside temperature, the inside temperature,
trying not to load the combustion chamber to the maximum capacity if not applicable so as not to
overheat the boiler.
At the ignition, after forming the embers bed, you can start filling in the fuel storage.
The following steps must be taken when feeding / refeeding:
1.
Open the door of the fuel storage.
2.
Load (complete) with fuel.
3.
Close the feeding door.
4.
The operating temperature will be adjusted.
1. thermomanometer
2. minimum thermostat (pellets burner)
3. led general switch
4. safety thermostat
5. safety fuse 6A
FEEDING
fig.29.
3 17.
ADJUSTEMENTS
Summary of Contents for FI-100NSP
Page 9: ...ver 2 9 Each boiler has its own identification plate IDENTIFICATION fig 1 ...
Page 12: ...ver 2 12 Side view Front view fig 5 fig 4 TECHNICAL DATA fig 6 fig 7 1 ...
Page 13: ...ver 2 13 fig 7 2 fig 7 3 TECHNICAL DATA ...
Page 34: ...ver 2 34 2 3 Burner s circuit diagram PELLETS BURNER fig 25 ...