![TERMET ThermElite TE125HLP Installation And Operating Instructions Manual Download Page 38](http://html1.mh-extra.com/html/termet/thermelite-te125hlp/thermelite-te125hlp_installation-and-operating-instructions-manual_1089165038.webp)
ISU-217:2004 cz
ęść
angielska
37
11. After the ionization current is being sensed by the monitoring electrode (after the
flame is lit up), check the voltage on the clamps of coil #2 (the system operates
properly at voltage of 0.9 – 1.5 V).
TROUBLESHOOTING
Models: TE125X, TE125H, TE80X, TE80H
Problem
Reasons
What to do
1 2
3
4
•
Disconnected electrode
conductor
•
Improve connection
•
Damaged electrode
•
Check - replace
•
Damaged spark generator
•
Check - replace
•
Run-down battery or damaged
hydro-generator
•
Check -replace
•
Badly adjusted micro-switch
•
Adjust the micro-switch by screwing
down the bolt placed on the micro-
switch lever. Make sure that after
adjustment there is no sparking when
there is no water flow..
•
Plugged water filter.(limited
water flow)
•
Remove impurity, clean, replace
1.
Lack of spark
(lack of ignition
during water
consumption)
•
Damaged elements in gas-water
unit
⇒
Damaged water membrane
⇒
Damaged control mechanism of
gas valve head
•
Replace gas-water unit or damaged
elements
•
Lack of gas supply (damaged
electrode)
•
Open the manual gas control valve
before the heater
•
Air in the gas line
•
Bleed the air out
•
Damaged ignition burner
•
Replace
2.
Ignition burner
does not light up
from the spark
•
Run-down battery or damaged
hydro-generator
•
Replace
•
Disconnected conductor of
supervision electrode
•
Improve connection
•
Damaged supervision electrode
•
Check -replace
•
Damaged spark generator
•
Check -replace
3.
Ignition burner
lights up, main
burner does not
light up
•
Damaged pressure differential
valve
•
Check -replace
4.
Attempted
ignition without
water flow
•
Badly adjusted micro-switch
•
Adjust the micro-switch by
unscrewing the bolt on the micro-
switch lever. Make sure that after the
adjustment there is no effect of
ignition delay while starting the
heater.