GAS PRESSURE REGULATOR 
 
NOTE: 

The tankless water heaters TE125X, TE125H, TE80X and TE80H are supplied 

with a gas pressure regulator that must be installed on the heater before attaching the 
gas supply line.  (See Fig.8) 
Failure to install the gas regulator as illustrated will violate the CSA certification of the 
unit.  The regulator supplied with the heater is pre-set to the correct pressure for the gas 
shown on the rating plate to the correct pressure

 

The pressure regulator provided with the heater is adjusted to deliver the proper gas (LP 
or NG) pressure (as indicated on the rating plate).

 

 

 
 

 
 
 
 
 
 
 
 

 

Fig.8

 

Gas Pressure Regulator 

 

 
 
 
 

Note

: An embossed arrow on the rear of the Gas Pressure Regulator indicates the flow 

direction of the fuel.  Always install the regulator with the arrow pointing in the direction 
of the heater inlet. 

 

 

WATER CONNECTIONS 

 
Install a manual in-line water control valve on the inlet water line.  Although water piping 
throughout your structure may be other than copper, we recommend that copper piping 
be used for at least three feet before and after the water heater.  Be sure to use a 
dielectric union to prevent electrolysis.  If the water heater is installed in a closed water 
system, means should be provided to control thermal expansion such the installation of 
a water expansion tank. Contact the water supplier, a certified plumber or the local 
plumbing inspector on how to handle this situation

 

Be sure to remove the plastic pipe stops (used for shipping purposes only) at the water 
connections before connecting the water pipes to the heater.  Connect the cold water 
pipe to the right water-in connection, as you face the heater.  Connect the hot water pipe 
to the left water-out connection, as you face the heater. 

 

 

NOTE: Models TE80P and TE125P are supplied with a gas pressure regulator that is 
built in the gas/water unit. 

Summary of Contents for ThermElite TE125HLP

Page 1: ...USE WITH NATURAL AND LIQUEFIED PETROLEUM GAS Suitable for potable water heating and space heating Models TE125PLP TE80PLP TE125PNG TE80PNG TE125XLP TE80XLP TE125XNG TE80XNG TE125HLP TE80HLP TE125HNG...

Page 2: ...f ignition system 36 Troubleshooting 37 Specification 41 WARNING If the information in this instruction manual is not followed exactly a fire or explosion may result causing property damage personal i...

Page 3: ...ge personal injury or death a Models without a pilot light are equipped with an electronic ignition device which automatically lights the burner Do not try to light the burner on these models having a...

Page 4: ...ted in Fig 1 Install two D Cell batteries in the battery compartment aligned as indicated Close the lid of the battery compartment Replacing the front shield can only be done when the temperature sele...

Page 5: ...exchanger and hot pipes and finally out of the faucet 7 When closing the hot water faucet the inflow of gas to both the ignition burner and the main burner is cut off and the water heater will shut of...

Page 6: ...knob gas water flow is turned to the extreme left position the Model 125 water heaters obtain their greatest flow of water 4 2 gallons per minute with the least rise in temperature Check the performan...

Page 7: ...close to a vent or a chimney as possible and in a place not exposed to possible freezing conditions 2 Keep the water heater area free and clear of combustible materials gasoline and other flammable l...

Page 8: ...f one square inch for every 10 000 BTU H of the maximum input rating of the unit One of these openings should be within 12 of the ceiling and the other should be within 12 of the floor EXHAUST VENTING...

Page 9: ...ar Extention Fig 5 Diagram of water and gas installation as well as exhaust venting Models TE80X TE80H Air grate min 5 Gas reducer max 12 liquefied gas supply Only for Air grate Connection to gas grid...

Page 10: ...lation as well as exhaust venting HOOD COLLAR EXTENTION The 4 Hood Collar Extension packed inside the carton must be installed at the very top of the heater before any other venting is attached Instal...

Page 11: ...on if a flex is used to connect the gas line Let a small amount of gas escape when you first smell the gas coming out of the loosened gas line to bleed the line and then securely reattach the nut on t...

Page 12: ...e heater inlet WATER CONNECTIONS Install a manual in line water control valve on the inlet water line Although water piping throughout your structure may be other than copper we recommend that copper...

Page 13: ...wall or above any floor covering which is combustible such as carpeting or area rugs The water heater must be securely attached to a load bearing wall Secure the two hooks provided with the heater to...

Page 14: ...12 4 25 5 8 14 1 6 7 1 4 Fig 10 Required mounting clearances to combustible and non combustible walls for models TE80X TE80H TE80P Note The design of the cabinet and the rear shield are designed in a...

Page 15: ...ar 5 Back cover subassembly Left and right screen 6 Heat exchanger 7 Main burner 8 Ignition burner subassembly 9 Gas water unit 11 Gas pressure regulator 12 Connector pipe 13 Connecting pipe subassemb...

Page 16: ...od 3 Angle bar 5 Back cover subassembly 6 Heat exchanger 7 Main burner 8 Ignition burner subassembly 9 Gas water unit 10 Hydro generator 11 Gas pressure regulator 12 Connector pipe 13 Connecting pipe...

Page 17: ...Heat exchanger 7 Main burner 8 Ignition burner subassembly 9 Gas water unit with gas pressure regulator 12 Connector pipe 13 Connecting pipe subassembly 14 Inlet pipe subassembly 15 Outlet pipe subass...

Page 18: ...ion burner subassembly 2 1 Ignition electrode 2 2 Supervision electrode 3 Gas water unit 3 1 Gas control knob 3 2 Temperature selection knob 3 3Gas filter 3 4 Inlet water filter 3 5 Pressure different...

Page 19: ...3 5 Electromagnetic valve 3 6 Gas pressure stabilizer 3 7 Piezo igniter 3 8 Gas filter of ignition burner 3 9 Gas adjusting screw of ignition burner 4 Heat exchanger 6 1 Temperature limiter as the pr...

Page 20: ...ISU 217 2004 cz angielska 19 PERFORMANCE CHART FOR MODELS TE125X TE125H TE125P Fig 16...

Page 21: ...ng applications Many such applications offer economical energy saving solutions for providing reliable hot potable water as well as radiant space heating The versatility of tankless gas water heaters...

Page 22: ...e PRV to appropriate discharge NOTES 1 Typical applications call for the TE125P TE125X or TE125H The TE80 SpaceMan models can be substituted if lower production capacity is acceptable 2 Maximum operat...

Page 23: ...off valve Cold Water In Hot Water Out NOTES 1 May be used with any model TE125 or TE80 ThermElite tankless hot water heater 2 Maximum operating temperature 185 F 3 For each ThermElite unit in the sys...

Page 24: ...rge Expansion Tank Secondary Pump Room Thermostat NOTES 1 May be used with any model TE125 or TE80 ThermElite tankless hot water heater 2 Maximum operating temperature 185 F 3 Maximum heating capacity...

Page 25: ...e NOTES 1 May be used with any model TE125 or TE80 ThermElite tankless hot water heater 2 Maximum operating temperature 185 F 3 Maximum heating capacity 40 F rise 20 F rise TE125 80 000 BTU hr 40 000...

Page 26: ...or soap bubbles which are a sign of a leak Never test for gas leaks using a match or flame A standard gas detector can also be used to test for leaks instead of using soapy water The manifold pressure...

Page 27: ...following checklist of parts from the conversion kit has been installed 1 Gas cone replacement part 1 piece was changed and installed 2 Gas cone seat part 1 piece was changed and installed 3 Main bur...

Page 28: ...TE80 LP 053 03 00 01 054 03 00 01 383 03 00 01 384 03 00 01 1 1 1 1 Inner diameter 8 30 6 59 8 43 6 75 Gas cone II TE125 NG TE125 LP TE80 NG TE80 LP 053 03 00 03 054 03 00 03 383 03 00 03 384 03 00 0...

Page 29: ...1 Designation blue brown blue brown REPLACEMENT OF GAS CONES AND GAS CONE SEATS IN THE GAS WATER UNIT BENEATH THE TEMPERATURE CONTROL KNOB Models TE125X TE125H TE80X TE80H Beneath the cover of the ga...

Page 30: ...s the one removed Insert the new gas cone seat paying special attention not to damage the sealing ring Secure the gas cone seat with a clamp paying special attention to properly place it in a slot Gas...

Page 31: ...do the mixers subassemblies left and right from the burner body 8 bolts Remove the old nozzles and screw in the new nozzles screw the nozzles in tightly paying special attention not to damage the thre...

Page 32: ...the nozzle from the seat and insert a new one Reconnect the pipe to the igniter Ignition burner Nozzle Fig 22 Igniter nozzle REPLACEMENT OF A NOZZLE IN THE IGNITION BURNER Models TE125P TE80P Undo th...

Page 33: ...TE80X TE80H Natural gas 7 3 7 10 8 Liquid Propane 11 10 3 2 The Maximum Gas Inlet Pressure 10 5 for Natural Gas and 13 5 for Propane must not be exceeded 1 Gas consumption refers to the listed gases...

Page 34: ...ensed plumber If repairs or service is required such repairs should likewise be done by a trained technician or knowledgeable plumber The following systems and parts should be checked at least once a...

Page 35: ...tion system against the outflow of flue gas to the room The temperature limiter item 10 see Fig 14 is a protection device against outflow of flue gas to room The temperature limiter is preset for 185...

Page 36: ...ion and ventilation air GENERAL REPAIR SERVICE DIAGNOSIS During production and assembly all ThermElite tankless gas water heaters undergo numerous quality assurance tests However occasionally during s...

Page 37: ...125X the spring in the battery compartment in heater TE80H and TE125H hydro generator conductor in white insulation 3 Connect the voltmeter to the positive end end located in heater TE 80X and TE125X...

Page 38: ...k of spark lack of ignition during water consumption Damaged elements in gas water unit Damaged water membrane Damaged control mechanism of gas valve head Replace gas water unit or damaged elements La...

Page 39: ...unit are adapted to gas that is being used Small discharge of water Check small water flow if the flow is smaller than 1 5 gal min must be adjusted with small water discharge screw 6 Heater overheats...

Page 40: ...eat exchanger get dirty in a short period of time Too much gas consumption Check adjust TE125P TE80P Problem Reason What to do 1 2 3 4 1 Heater does not start up ignition burner does not heat the end...

Page 41: ...s of gas water unit replace the gas water unit with the new one 3 Heater overheats the water badly set gas pressure regulator readjust the gas pressure regulator to the local conditions improper gas c...

Page 42: ...for other uses a means such as a mixing valve shall be installed to temper the water for those uses in order to reduce scald hazard potential MANUFACTURER Termet S A Ul Walbrzyska 33 58 160 Swiebodzic...