less than 3 Pa (0.03 mbar) and not more than 15 Pa 
(0.15mbar).  
 

3.1.5  Gas system 

Gas  appliances  should  be  permanently  connected  to 
steel or copper pipes of the gas system or by means of 
metal tubes. 

Liquefied gas system 

  Gas  appliances  fed  with  liquefied  gas  cannot  be 

installed  in  rooms  where  the  floor  level  is  situated 
under the ground level. 

 

The cylinders should be situated in a distance not less 
than  1.5  m  from  heat  radiating  surfaces  (radiators, 
stoves, etc.).

 

  The  cylinders  cannot  be  exposed  to  radiation  of 

places with open fire. 

  The cylinders should be situated in vertical position, 

protected against falls, beats, from children etc. 

  The  cylinders  should  be  placed  in  a  distance  of  at 

least  1  m  from  devices  likely  to  cause  electric 
sparkling, e.g. electricity meters. 

  The  room  temperature  where  the  cylinder  will  be 

located cannot 35

o

C. 

Recommendation: 

Because the one gas cylinder with the capacity of 11 kg 
in the exploitation of the water heater is sufficient for a 
short  time,  it  is  recommended  to  use  a  set  of  11-kg 
cylinders, so called battery, or a bigger cylinder with the 
capacity  above  11kg.  Such  a  battery  or  (max.  10 
cylinders) or a larger cylinder should be placed outside 
the building. 
 

3.2  Preliminary check-up 

operations 

Before installation, it is necessary to check if:  

  the purchased water heater is adapted for combustion 

the type of gas supplied from the gas mains which the 
appliance  will  be  connected  to.  The  type  of  gas  the 
water heater has been adapted for is designated  on 
the  packaging  and  the  marking  plate  placed  on  the 
front cover. 

  the  water  system  has  been  rinsed  thoroughly  with 

water, in order to get rid of possible rust, scale, sand 
or other foreign matter, which could disturb the proper 
operation  of  the  water  heater  (e.g.  increase  the 
resistance of water flow in the system). 

 

3.3  Water heater mounting  

Water heater should be installed in a place not posing 
significant difficulties for a service team, on a wall made 
of  non-flammable  materials  or  isolated  from  an 
inflammable  wall  with  a  plate  made  of  non-flammable 
material. 
In case of building the  water heater over in a furniture 
system, air supply necessary for proper gas combustion 
should be provided (Illus. 3.3.1).  

Do not mount the water heater in the neighborhood of 
appliances  likely  to  disturb  its  operating  (e.g.  over  a 
cooker from which vapors rise). 
Mount the water heater on the wall, on hooks 
permanently fixed in  it, using two rectangular notches 
on the water heater back cover. 

 

Fig. 3.3.1 Required mounting distances 

3.4  Connecting to the gas supply  

Fig.3.6.1 shows the connection diameters. For gas pipe, 
the diameter is G3/4.  
Gas water heaters not equipped with gas flow stabilizer 
are adopted to be installed in the gas system equipped 
with  individual  mean  pressure  reducer.  Cables  with  a 
valid certificate should be used for installation. 

On  the  system  pipe  should  be  installed  a  cut  off 
valve  and  a  gas  filter.  Installing  the  gas  filter  is 
necessary for correct and long-lasting operation of 
the gas unit and the burner. Filter is not included in 
the installation kit. 
 

3.5  Connecting to the water supply  

Fig.3.6.1  shows  the  connection  diameters.  For  water 
pipe, the diameter is G1/2. On the system pipe should 
be installed a cut-off valve.  
Connecting the water heater to the water supply system 
should be performed by means of flexible connectors or 
stiff  pipes.  These  pipes  are  not  included  in  the 
installation kit. 
The connection to the water system should be made in 
such  a  way  that  the  geometry  of  the  water  heater  is 
maintained. Incorrect execution of the connection may 
cause distortion of the water heater, which may make it 
impossible to mount the knobs or lead to their blocking.  

In  order  to  stop  mechanical  pollution,  and  thus, 
provide the water heater reliability and its long-term 
operation,  a  water  filter  should  be  installed  on  the 
supplying  pipe.  The  filter  must  not  cause  any 
resistance  for  a  water  flow  and  should  be  easy 
cleaning. The filter is not included in the basic water 
heater equipment. 

Summary of Contents for TERMAQ AQUA-POWER ECO GH-19-02

Page 1: ...TA 1450 012 12 INSTALLATION AND OPERATION MANUAL Instantaneous gas water heater...

Page 2: ...ndards Please take time to get yourself familiarised with this manual as full understanding of the product s functions as well as knowledge of manufacturer s recommendations is imperative for its smoo...

Page 3: ...8 4 WATER HEATER OPERATION 8 4 1 Preparing the water heater for the first start up 8 4 2 Water heater starting up 9 4 3 Water temperature and water flow regulation 9 4 4 Water heater switching off 10...

Page 4: ...ater can be operated only by adults Do not perform any repairs or alterations to the water heater on your own It is strictly forbidden to make any modifications that could reduce the clearance of air...

Page 5: ...ters ensure proportional power regulation which enables to get constant temperature of outflowing water Activation burner ignition of the water heater takes place with each opening of the tap Shutdown...

Page 6: ...ential pressure valve 3 5 1 Coil I of the differential pressure valve 3 5 2 Coil II of the differential pressure valve 3 6 Regulating screw of the microswitch 3 7 Regulating screw of the little water...

Page 7: ...perature in the heat exchanger exceeds 950C by cutting off the voltage in the supply system and also closing the gas supply to the burner It is forbidden to make any modifications in the water heater...

Page 8: ...ater heater is installed there should be a non closing hole of exhaust ventilation with the surface not smaller than 200 cm2 placed as close to the ceiling as possible It is not allowed to use mechani...

Page 9: ...g significant difficulties for a service team on a wall made of non flammable materials or isolated from an inflammable wall with a plate made of non flammable material In case of building the water h...

Page 10: ...irst start up Before proceeding with the first start up of the water heater it is necessary to Fill the water system with water so as after turning on the water taps water may flow This ensures that t...

Page 11: ...rning off the hot water tap the gas supply to the burner will be cut off 4 3 Water temperature and water flow regulation Water heaters are equipped with modern gas water fittings ensuring proportional...

Page 12: ...ssions Gas type CO emissions ppm 1 2E G20 58 5 3P G30 48 4 3B G30 48 4 3P B G31 490 155 1 CO concentration for maximum gas pressure Pmax 5 2 Gas consumption values Gas type Range of kinetic gas pressu...

Page 13: ...such case the fittings should be taken out the water heater Then take out the filter clean it and assembly again Fig 5 4 1 Fig 6 4 1 Water gas fittings 6 4 Safety system checking During every inspecti...

Page 14: ...uctions 1 Check the correctness of electric connections 2 Connect a voltmeter to the pole In TERMAQ ELECTRONIC ECO water heaters spring in battery compartment item 6 In TERMAQ AQUA POWER ECO water hea...

Page 15: ...out the whole burner Control electrode wire is disconnected Correct the connection Damaged control electrode Check replace Damaged spark generator Check replace Damaged differential pressure valve Che...

Page 16: ...et to water gas fittings is damaged Replace gasket with a new one One of the gaskets on the outlet from water gas fittings or on the inlet to burner is damaged Replace gasket with a new one Water gas...

Page 17: ...IO 752 2018 EN 05 12 2018 D uga 13 58 160 wiebodzice Infoline 48 74 856 08 01 48 74 854 68 90 http www termet com pl export termet com pl termet termet com pl...

Reviews: