performed with the use of agents available on market, 
according to the recommendations of agent producer. 
The  scale  can  also  be  removed  by  means  of  10-20% 
acetic acid, by keeping it in the heat exchanger for about 
3 hours. After this operation, the exchanger should be 
thoroughly rinsed with clean water. 

 

Fig. 6.1.1. Heat exchanger 

Do  not  use  the  wire  brushes,  or  another  brushes  with 
hard bristle  

6.1  Burner maintenance  

During  the  burner  maintenance  the  plates  on  the 
segments  should  be  cleaned  by  means  of  soft  brush 
(not the wire one). Pay attention whether the plates or 
segments were not damaged. 

6.2  Water filter cleaning  

In case of notifying too small stream of water flowing out 
from the water heater and difficulty in igniting the burner, 
the  water  supply  valve  and  the  gas  valve  on  the 
appliance  connection  should  be  shut  down.  Check  up 
and  clean  the  water  filter  on  the  water  pipes  on  the 
appliance connection. Sometimes may occur choking of 
the  internal  filter  in  the  water  assembly.  Then  fittings 
should  be  taken  out  from  the  water  heater.  The  filter 
should  be  dismounted,  cleaned  and  mounted  again 
(Fig.5.4.1). 

6.3  Gas filter cleaning 

In case of finding too poor stream of gas flowing out of 
the  main  burner  and  difficulties  in  burner  ignition,  the 
valve  on  the  water  supply  line  and  gas  valve  on  the 
appliance  connection  with  the  gas  supplying  system 
should be shut down. Check up and clean the gas filter 
situated  on  the  appliance  connection  with  the  gas 
supplying  system.  Occasionally  may  appear  the 
situation of choking inside filter of gas 

– water fittings. In 

such  case  the  fittings  should  be  taken  out  the  water 
heater.  Then  take  out  the  filter,  clean  it  and  assembly 
again. (Fig. 5.4.1) 
 

 

 

Fig.6.4.1 Water-gas fittings 

 

6.4  Safety system checking  

During  every  inspection  correctness  of  the  protection 
systems  operation  should  be  checked  as  well  and 
tightness 

of 

the 

gas 

fittings 

as 

well.  

 

6.4.1  Checking  the  protections  against 

flue gas outflow into the room 

Temperature limiter (Illus.  2.2.1.1 item 10) - protection 
against  gas  outflow  into  the  room,  is  set  for  the 
temperature 85±3°C (GE-19-02, GH-19-02). 
In order  to  verify  the  correctness  of  the  limiter  setting, 
the following operations should be performed: 

 

prepare a metal vessel with a thermometer, 

 

fill the vessel with a liquid, 

 

take  the  limiter  out  of  the  holder  (unscrew  the 
screws), put it into a vessel submerging in the liquid 
only the metal cap  

 

heat the liquid up to the temperature of 82°C (GE-
19-02, GH-19-02) 

– in such temperature the limiter 

should not actuate, 

 

heat the liquid up to 88°C (GE-19-02, GH-19-02) – 
in such temperature the limiter should actuate. 

A  properly  operating  limiter  should  disconnect  electric 
contacts  in  the  temperature  range  from  82°C  to  88°C 
(GE-19-02, GH-19-02). 

6.4.2  Checking the protection against heat 

exchanger overheating  

Temperature  limiter  (Fig.  2.2.1.1  item  11)  -  protection 
against exceeding the upper limit of water temperature 
– is set for the temperature 75±3°C (GE-19-02, GH-19-
02).  In  order  to  verify  the  correctness  of  the  limiter 
setting, operations as above should be performed.  
A  properly  operating  limiter  should  disconnect  electric 
contacts  in  the  temperature  range  from  72°C  to  78°C 
(GE-19-02, GH-19-02). 

During every next re-assembly of the water and gas 
system, new seals should be used. 

The actions mentioned in section 6 are not covered 
by warranty repairs.  

 
 

water filter 

gas filter 

Summary of Contents for TERMAQ AQUA-POWER ECO GH-19-02

Page 1: ...TA 1450 012 12 INSTALLATION AND OPERATION MANUAL Instantaneous gas water heater...

Page 2: ...ndards Please take time to get yourself familiarised with this manual as full understanding of the product s functions as well as knowledge of manufacturer s recommendations is imperative for its smoo...

Page 3: ...8 4 WATER HEATER OPERATION 8 4 1 Preparing the water heater for the first start up 8 4 2 Water heater starting up 9 4 3 Water temperature and water flow regulation 9 4 4 Water heater switching off 10...

Page 4: ...ater can be operated only by adults Do not perform any repairs or alterations to the water heater on your own It is strictly forbidden to make any modifications that could reduce the clearance of air...

Page 5: ...ters ensure proportional power regulation which enables to get constant temperature of outflowing water Activation burner ignition of the water heater takes place with each opening of the tap Shutdown...

Page 6: ...ential pressure valve 3 5 1 Coil I of the differential pressure valve 3 5 2 Coil II of the differential pressure valve 3 6 Regulating screw of the microswitch 3 7 Regulating screw of the little water...

Page 7: ...perature in the heat exchanger exceeds 950C by cutting off the voltage in the supply system and also closing the gas supply to the burner It is forbidden to make any modifications in the water heater...

Page 8: ...ater heater is installed there should be a non closing hole of exhaust ventilation with the surface not smaller than 200 cm2 placed as close to the ceiling as possible It is not allowed to use mechani...

Page 9: ...g significant difficulties for a service team on a wall made of non flammable materials or isolated from an inflammable wall with a plate made of non flammable material In case of building the water h...

Page 10: ...irst start up Before proceeding with the first start up of the water heater it is necessary to Fill the water system with water so as after turning on the water taps water may flow This ensures that t...

Page 11: ...rning off the hot water tap the gas supply to the burner will be cut off 4 3 Water temperature and water flow regulation Water heaters are equipped with modern gas water fittings ensuring proportional...

Page 12: ...ssions Gas type CO emissions ppm 1 2E G20 58 5 3P G30 48 4 3B G30 48 4 3P B G31 490 155 1 CO concentration for maximum gas pressure Pmax 5 2 Gas consumption values Gas type Range of kinetic gas pressu...

Page 13: ...such case the fittings should be taken out the water heater Then take out the filter clean it and assembly again Fig 5 4 1 Fig 6 4 1 Water gas fittings 6 4 Safety system checking During every inspecti...

Page 14: ...uctions 1 Check the correctness of electric connections 2 Connect a voltmeter to the pole In TERMAQ ELECTRONIC ECO water heaters spring in battery compartment item 6 In TERMAQ AQUA POWER ECO water hea...

Page 15: ...out the whole burner Control electrode wire is disconnected Correct the connection Damaged control electrode Check replace Damaged spark generator Check replace Damaged differential pressure valve Che...

Page 16: ...et to water gas fittings is damaged Replace gasket with a new one One of the gaskets on the outlet from water gas fittings or on the inlet to burner is damaged Replace gasket with a new one Water gas...

Page 17: ...IO 752 2018 EN 05 12 2018 D uga 13 58 160 wiebodzice Infoline 48 74 856 08 01 48 74 854 68 90 http www termet com pl export termet com pl termet termet com pl...

Reviews: