TROUBLESHOOTING
TROUBLE
POSSIBLE
CAUSE
REMEDY
11.Lamp will not start
e.Improper ballast
e.The ballast name plate data should
agree with the line voltage and lamp
used. If not, replace the ballast.
f.Lamp has been operating; cool
f.Switch off breaker and allow lamp
down time insufficient
to cool.
12.Lamp starts slowly (arc does
a.Defective lamp
a.Lamp may glow for an extended
not strike when switch is first
period of time. Replace after
turned
on
checking
voltage
and
ballast
13.Circuit breaker trips on lamp
a.Short circuit or ground
a.Check wiring against diagram.
startup
inspect
for
shorts
or
ground.
Fix
as
needed.
14.Lamp light output low
a.Normal lamp depreciation
a.Replace lamp
b.Dirty lamp or fixture
b.Clean lamp and fixture
c.Defective ballast
c.Interchange ballast plugs. If lamp
starts, replace ballast. Check for
swollen capacitors, charred wiring,
core and coil, or other signs of
excessive heat.
d.Wrong voltage
d.Check line voltage at ballast input.
Voltage should be within 10% of
e.Improper ballast
e.Check ballast name plate against
lamp data
15.Lamp colors different
a.Normal lamp depreciation
a.Replace lamp
b.Dirty lamp or fixture
b.Clean lamp and fixture
c.Wrong lamp
c.Check data on lamps and replace
as needed.
16.Arc tube discolored or swollen
a.Over voltage from power supply
b.Improper ballast
b.Check ballast name plate against
lamp data
17.Short lamp life
a.Lamp damaged
a.Check for outer bulb cracks,
cracks where lamp meets base, and
for broken arc tube or loose metal
parts. Replace as needed.
b.Improper ballast
b.Check ballast name plate against
lamp data
18.Lamp flickers or goes out-
a.Improper Ballast
a.Check ballast name plate against
intermittent
or
cycling
lamp
data
b.New lamp
b.Under certain conditions new lamps
may "cycle". Usually after 3 tries to
start at 30 to 60 second intervals,
lamp will stabilize and operate normal
rating when operating at normal load.
Check wiring connections for voltage
loss. Check socket contact point.
a.Check voltage at ballast, for current
or voltage surges, for shorted
capacitors and replace as needed
Summary of Contents for RL4000D2
Page 23: ...November2006 22 RL4000LightTower Part No 833005 Rev A SPECIFICATIONS DIMENSIONS...
Page 34: ...November2006 Part No 833005 Rev A RL4000LightTower 33 MODEL NUMBER IDENTIFICATION...
Page 38: ...November 2006 Part No 833005 Rev A RL4000 Light Tower 37 Wiring Diagrams Section...
Page 39: ...November 2006 38 RL4000 Light Tower Part No 833005 Rev A Fixture Wiring Diagram...
Page 40: ...November 2006 Part No 833005 Rev A RL4000 Light Tower 39 1000MH Ballast Diagram...
Page 41: ...November 2006 40 RL4000 Light Tower Part No 833005 Rev A 1000HPS Ballast Diagram...
Page 42: ...November 2006 Part No 833005 Rev A RL4000 Light Tower 41 AC Wiring For A Light Tower Diagram...
Page 43: ...November 2006 42 RL4000 Light Tower Part No 833005 Rev A DC Engine Wiring Diagram...
Page 44: ...November 2006 Part No 833005 Rev A RL4000 Light Tower 43 Consolidated Coil Cord With Plug End...
Page 45: ...November 2006 44 RL4000 Light Tower Part No 833005 Rev A This page intentionally left blank...
Page 46: ...November 2006 Part No 833005 Rev A RL4000 Light Tower 45 Parts Catalog Section...
Page 49: ...November 2006 48 RL4000 Light Tower Part No 833005 Rev A This page intentionally left blank...
Page 51: ...November 2006 50 RL4000 Light Tower Part No 833005 Rev A FRAME ASSEMBLY...
Page 53: ...November 2006 52 RL4000 Light Tower Part No 833005 Rev A CABINET ASSEMBLY...
Page 61: ...November 2006 60 RL4000 Light Tower Part No 833005 Rev A FIXTURE ASSEMBLY...