Operator's Manual
Second Edition • Third Printing
Inspections
30
GS™-2669RT • GS™-3369RT • GS™-4069RT
Part No. 1298222GT
At the Ground Controls
1 Select a test area that is firm, level and free of
hazards.
2 Pull out the platform and ground red
Emergency Stop button to the on position.
3 Turn the key switch to ground control.
Result: The LCD screen will come on and
display
SYSTEM READ
y.
Note: In cold climates, the LCD readout screen will
need to warm up before the display appears.
4 Start the engine. See Operating Instructions
section.
Test Emergency Stop
5 Push in the red Emergency Stop button to the
off position.
Result: The engine should shut off and no
functions should operate.
6 Pull out the red Emergency Stop button to the
on position and restart the engine.
Test the Up/Down Functions
The audible warnings on this machine and the
standard horn all come from the same central
alarm. The horn is a constant tone. The descent
alarm sounds at 60 beeps per minute. The alarm
that goes off when the machine is not level sounds
at 180 beeps per minute.
7 Do not press the lift function enable
button. Press and hold the platform
up button.
Result: The platform should not raise.
8 Press and hold the lift function enable button.
Press and hold the platform up button.
Result: The platform should raise.
9 Press and hold the lift function enable button.
Press and hold the platform down button.
Result: The platform should lower. The
descent alarm should sound while the platform
is lowering.
Summary of Contents for GS69F-18000