Inspections
Part No. 1298222GT
GS™-2669RT • GS™-3369RT • GS™-4069RT
31
Test the Tilt Sensor Operation
Note: Perform this test from the ground with the
platform controller. Do not stand in the platform.
10 Fully lower the platform.
11 Place a 2x4 or similar piece of wood under
both wheels on one side and drive the
machine up onto them.
12 Raise the platform approximately 7 ft / 2.13 m.
Result: The platform should stop and the tilt
alarm will sound at 180 beeps per minute. The
platform controls LED readout should display
LL and the ground controls LCD should
display LL: Machine Tilted.
13 Press the drive function button.
14 Press and hold the function enable switch on
the control handle.
15 Move the control handle in the direction
indicated by the blue arrow, then move the
control handle in the direction indicated by the
yellow arrow.
Result: The drive function should not work in
either direction.
16 Lower the platform and remove both pieces of
wood.
At the Platform Controls
Test Emergency Stop
17 Push in the platform red Emergency Stop
button to the off position.
Result: The engine should shut off and no
functions should operate.
18 Pull out the red Emergency Stop button to the
on position and restart the engine.
Result: The indicator light
should be green.
Test the Horn
19 Press the horn button.
Result: The horn should sound.
Summary of Contents for GS69F-18000