Cable Track
The primary boom cable track guides the cables
and hoses running up the boom. It can be repaired
link by link without removing the cables and hoses
that run through it. Removing the entire primary
boom cable track is only necessary when
performing major repairs that involve removing the
primary boom.
How to Remove the Cable Track
Note: When removing a hose assembly or fitting,
the O-ring (if equipped) on the fitting and/or hose
end must be replaced. All connections must be
torqued to specification during installation. Refer to
Specifications,
Hydraulic Hose and Fitting Torque
Specifications.
1 cable track tray
2 cable track
3 cable track pull tube
4 primary boom
5 pin
6 snap ring
1 Tag and disconnect the wire connectors from
the bottom of the platform control box.
Note: When installing the wire connectors to the
bottom of the platform control box, match the color
of the connectors to those on the control box to be
sure they are installed in the correct location.
2 Disconnect the power to plat cable from the
AC outlet box.
3 Remove the hose and cable clamps from the
platform support.
4 Tag, disconnect and plug the platform leveling
slave cylinder hydraulic hoses from the
bulkhead fittings on the top of the primary
boom. Cap the bulkhead fittings.
Bodily injury hazard. Spraying
hydraulic oil can penetrate and
burn skin. Loosen hydraulic
connections very slowly to allow
the oil pressure to dissipate
gradually. Do not allow oil to
squirt or spray.
5 Tag, disconnect and plug ports V1 and V2 on
the platform rotate/jib manifold. Cap the
fittings.
6 Remove the hose and cable cover from the
side of the jib boom.
7 Remove the retaining fasteners securing the
cable track pull tube.
8 Pull the cable track back from the pull tube.
9 Remove the hose and cable clamps from
inside the cable track at both ends.
10 Pull the hoses and cables out of the cable
track pull tube.
11 Pull the hoses and cables out of the cable
track.
12 Remove the retaining fasteners that attach
the cable track to the cable track tray.
13 Remove the cable track from the machine.
Summary of Contents for Genie Z-60 DC
Page 57: ...August 2022 Service and Repair Manual Manifolds Part No 1307785GT Z 60 DC Z 60 FE 45 ...
Page 59: ...August 2022 Service and Repair Manual Manifolds Part No 1307785GT Z 60 DC Z 60 FE 47 ...
Page 153: ...August 2022 Service and Repair Manual 141 Wiring Diagram Options from Z60H 2548 to 2999 ...
Page 156: ...Service and Repair Manual August 2022 144 Wiring Diagram Options from Z60H 2548 to 2999 ...
Page 160: ...Service and Repair Manual August 2022 148 Power Cable Wiring Diagram from Z60H 2548 to 2999 ...
Page 161: ...August 2022 Service and Repair Manual 149 Wiring Diagram FE Models from Z60H 3000 Z60M 1000 ...
Page 164: ...Service and Repair Manual August 2022 152 Wiring Diagram DC Models from Z60H 3000 Z60M 1000 ...
Page 165: ...August 2022 Service and Repair Manual 153 Electrical Schematic from Z60H 2548 to 2999 ...
Page 168: ...Service and Repair Manual August 2022 156 Electrical Schematic from Z60H 2548 to 2999 ...
Page 177: ...August 2022 Service and Repair Manual 165 Electrical Schematic PCON from Z60H 2548 to 2999 ...
Page 180: ...Service and Repair Manual August 2022 168 CAN BUS Wiring Diagram from Z60H 2548 to 2999 ...
Page 181: ...August 2022 Service and Repair Manual 169 Electrical Schematic DCON from Z60H 3000 Z60M 1000 ...
Page 184: ...Service and Repair Manual August 2022 172 Electrical Schematic GCON from Z60H 3000 Z60M 1000 ...
Page 185: ...August 2022 Service and Repair Manual 173 Electrical Schematic PCON from Z60H 3000 Z60M 1000 ...
Page 188: ...Service and Repair Manual August 2022 176 Electrical Schematic TCON from Z60H 3000 Z60M 1000 ...
Page 189: ...August 2022 Service and Repair Manual 177 Wiring Diagram CAN BUS from Z60H 3000 Z60M 1000 ...
Page 191: ...August 2022 Service and Repair Manual 179 Hydraulic Schematic ...
Page 193: ......