Service and Repair Manual
August 2022
Drive Control Fault Codes
110
Z
®
-60 DC • Z
®
-60 FE
Part No. 1307785GT
CAN
Object
Flash
Pattern
Description & Fault
Type
Cause
Effect
Solution
2134
1-10
Travel Control
Supervision
1. With the vehicle in the
stopped state, the detected
motor frequency and/or
phase current exceeds the
limit set by the Travel
Control Supervision
parameter
2. Mis-adjusted Travel
Control Supervision
parameters
See: Programmer »
Application Setup » Travel
Control Supervision menu
ShutdownVehicle:
ShutdownMotor
ShutdownMainContactor
ShutdownEMBrake
ShutdownThrottle
FullBrake
ShutdownPump
Set: The motor frequency
and/or and phase-current
are above their Travel
Control Supervision settings
when in the stopped state
Clear:
Reset Controller
2109
1-11
Critical OS General
Fault
Program execution
within the controller
encountered a critical
problem and could
not recover from this
(<100) Internal Fault, kindly
contact your Curtis
representative immediately
(>100) Ill-formed or
corrupted application
package was loaded into
controller
ShutdownAll;
Set:
(<100) Internal Fault
(>100) CIT version is too old
to fully support the FOS
version
Clear:
(<100) Internal Fault
(>100) Update CIT
version, re-package the
project, and re-flash the
application package
210A
1-12
OS General 2 Fault
Program execution
within the controller
encountered a
serious problem and
could not recover
from this
(<100) Internal Fault, kindly
contact your Curtis
representative immediately
(>100) Ill-formed or
corrupted application
package was loaded into
controller
ShutdownAll;
Set:
(<100) Internal Fault
(>100) CIT version is too old
to fully support the FOS
version
Clear:
(<100) Internal Fault
(>100) Update CIT version,
re-package the project, and
re-flash the application
package
2110
1-13
Reset Rejected
1. NMT Reset Rejected
2. Reset_Controller ()
Rejected
Shutdown Interlock;
Shutrdown Throttlel;
Clear:
Reset Controller
2140
2-2
Controller Overtemp
Cutback
1. Controller is operating in
an extreme environment
2. Excessive load on vehicle
Improper mounting of
controller which is
preventing controller cooling
3. Controller is performance-
limited at this temperature
See Programmer » System
Monitor menu » Controller:
Temperature
Reduced drive torque
Reduced regen-braking
torque.
Fault Action:
None, unless a fault
action is programmed in
VCL
Set: Controller’s Heatsink
temperature exceeded 85°C
Clear: Bring heatsink
temperature below 85°C
Summary of Contents for Genie Z-60 DC
Page 57: ...August 2022 Service and Repair Manual Manifolds Part No 1307785GT Z 60 DC Z 60 FE 45 ...
Page 59: ...August 2022 Service and Repair Manual Manifolds Part No 1307785GT Z 60 DC Z 60 FE 47 ...
Page 153: ...August 2022 Service and Repair Manual 141 Wiring Diagram Options from Z60H 2548 to 2999 ...
Page 156: ...Service and Repair Manual August 2022 144 Wiring Diagram Options from Z60H 2548 to 2999 ...
Page 160: ...Service and Repair Manual August 2022 148 Power Cable Wiring Diagram from Z60H 2548 to 2999 ...
Page 161: ...August 2022 Service and Repair Manual 149 Wiring Diagram FE Models from Z60H 3000 Z60M 1000 ...
Page 164: ...Service and Repair Manual August 2022 152 Wiring Diagram DC Models from Z60H 3000 Z60M 1000 ...
Page 165: ...August 2022 Service and Repair Manual 153 Electrical Schematic from Z60H 2548 to 2999 ...
Page 168: ...Service and Repair Manual August 2022 156 Electrical Schematic from Z60H 2548 to 2999 ...
Page 177: ...August 2022 Service and Repair Manual 165 Electrical Schematic PCON from Z60H 2548 to 2999 ...
Page 180: ...Service and Repair Manual August 2022 168 CAN BUS Wiring Diagram from Z60H 2548 to 2999 ...
Page 181: ...August 2022 Service and Repair Manual 169 Electrical Schematic DCON from Z60H 3000 Z60M 1000 ...
Page 184: ...Service and Repair Manual August 2022 172 Electrical Schematic GCON from Z60H 3000 Z60M 1000 ...
Page 185: ...August 2022 Service and Repair Manual 173 Electrical Schematic PCON from Z60H 3000 Z60M 1000 ...
Page 188: ...Service and Repair Manual August 2022 176 Electrical Schematic TCON from Z60H 3000 Z60M 1000 ...
Page 189: ...August 2022 Service and Repair Manual 177 Wiring Diagram CAN BUS from Z60H 3000 Z60M 1000 ...
Page 191: ...August 2022 Service and Repair Manual 179 Hydraulic Schematic ...
Page 193: ......