Secondary Boom Lift Cylinder
There is one secondary boom lift cylinder
incorporated in the structure of the secondary boom
assembly. This cylinder requires hydraulic pressure
to extend and retract. The secondary boom lift
cylinder is equipped with counterbalance valves to
prevent movement in the event of a hydraulic line
failure.
How to Remove the Secondary
Boom Lift Cylinder
Bodily injury hazard. This
procedure requires specific repair
skills, lifting equipment and a
suitable workshop. Attempting
this procedure without these skills
and tools could result in death or
serious injury and significant
component damage. Dealer
service is strongly recommended.
Note: When removing a hose assembly or fitting,
the O-ring (if equipped) on the fitting and/or hose
end must be replaced. All connections must be
torqued to specification during installation. Refer to
Specifications,
Hydraulic Hose and Fitting Torque
Specifications.
1
Raise the secondary boom until the barrel end
pivot pins of the secondary lift cylinder clear
the lower tension arms.
2
Attach a lifting strap from an overhead crane
(5 ton / 5000 kg) to the pivot end of the primary
boom for support. Do not apply lifting pressure.
Crushing hazard. The boom
assembly can fall if not properly
supported by the overhead
crane.
Component damage hazard.
Hoses and cables can be
damaged if they are kinked or
pinched.
3
Remove the pin retaining fasteners securing
the barrel-end pivot pins of the secondary
boom lift cylinder. Do not remove the pins.
4
Attach a strap from an overhead crane to the
center of the secondary boom lift cylinder for
support. Do not apply lifting pressure.
Crushing hazard. The secondary
boom lift cylinder could become
unbalanced and fall when
removed from the machine if not
properly attached to the
overhead crane.
5
Use a slide hammer to remove the pivot pins.
6
Use auxiliary power to retract the cylinder.
7
Tag, disconnect and plug the hydraulic hoses
from the secondary boom lift cylinder. Cap the
fittings on the cylinder.
Bodily injury hazard. Spraying
hydraulic oil can penetrate and
burn skin. Loosen hydraulic
connections very slowly to allow
the oil pressure to dissipate
gradually. Do not allow oil to
squirt or spray.
Summary of Contents for Genie Z-60 DC
Page 54: ...Service and Repair Manual December 2018 Manifolds 44 Z 60 37 DC Z 60 37 FE Part No 1271125GT ...
Page 56: ...Service and Repair Manual December 2018 Manifolds 46 Z 60 37 DC Z 60 37 FE Part No 1271125GT ...
Page 107: ...December 2018 Service and Repair Manual 97 Wiring Diagram Options ...
Page 110: ...Service and Repair Manual December 2018 100 Schematics Options 4WD DC and FE Models ...
Page 111: ...December 2018 Service and Repair Manual 101 Power Cable Wiring Diagram ...
Page 113: ...December 2018 Service and Repair Manual 103 Hydraulic Schematic DC and FE Models ...
Page 115: ...December 2018 Service and Repair Manual 105 Electrical Schematic DC FE Models ...
Page 118: ...Service and Repair Manual December 2018 108 Electrical Schematic DC FE Models ...
Page 120: ...Service and Repair Manual December 2018 110 Electrical Schematic DC FE Models ...
Page 125: ......