Operator's Manual
First Edition • First Printing
Inspections
32 Z
®
-45 XC
™
Part No. 1301594GT
At the Ground Controls
1
Select a test area that is firm, level and free of
hazards.
2
Turn the key switch to ground control.
3
Pull out the red Emergency Stop button to the
on position.
Result: The beacon (if equipped) should flash.
4
Start the engine. See Operating Instructions
section.
Test Emergency Stop
5
Push in the red Emergency Stop button to the
off position.
Result: The engine will shut off after 2 to
3 seconds.
6
Pull out the red Emergency Stop button to the
on position and restart the engine.
Test Machine Functions
7
Do not push and hold the
function enable button.
Attempt to activate each
boom and platform function
toggle switch.
Result: No boom and platform functions should
operate.
8
Press and hold the function enable button and
activate each boom and platform function
toggle switch.
Result: All boom and platform functions should
operate through a full cycle. The descent
alarm should sound while the boom is
lowering.
Test the Tilt Sensor
9
Turn the key switch to
platform control. Pull out the
platform red Emergency
Stop button to the on
position.
10
Open the engine side
turntable cover and locate
the tilt sensor to the right of
the hydraulic pump.
11
Press down one side of the tilt sensor.
Result: The alarm, located in the platform,
should sound.
Test Emergency Controls
12
Turn the key switch to ground control and shut
the engine off.
13
Pull out the red Emergency Stop button to the
on position.
14
Simultaneously hold the
emergency power switch on and
activate each boom function toggle
switch.
Note: To conserve battery power, test each
function through a partial cycle.
Result: All boom functions should operate.