5 Move the platform up and down by hand, so it
bounces approximately 2.5 to 5 cm / 1 to
2 inches. Allow the platform to settle.
Result: The overload indicator lights are off
and the alarm does not sound. Proceed to
step 6.
Result: The overload indicator lights are
flashing at the platform and ground controls,
and the alarm is sounding. Slowly tighten the
load spring adjustment nut in a clockwise
direction in 10° increments until the overload
indicator light turns off, and the alarm does
not sound. Proceed to step 8.
Note: The platform will need to be moved up and
down and allowed to settle between each
adjustment.
Note: There may be a 2 second delay before the
platform overload indicator light and alarm
responds.
6 Move the platform up and down by hand, so it
bounces approximately 2.5 to 5 cm / 1 to
2 inches. Allow the platform to settle.
Result: The overload indicator lights are off at
the platform and ground controls, and the
alarm does not sound. Slowly loosen the load
spring adjustment nut in a counterclockwise
direction in 10° increments until the overload
indicator light flashes at both the platform and
ground controls, and the alarm sounds.
Proceed to step 7.
Result: The overload indicator lights are
flashing at the platform and ground controls,
and the alarm is sounding. Repeat this
procedure beginning with step 5.
Note: The platform will need to be moved up and
down and allowed to settle between each
adjustment.
Note: There may be a 2 second delay before the
platform overload indicator lights and alarm
responds.
7 Move the platform up and down by hand, so it
bounces approximately 2.5 to 5 cm / 1 to
2 inches. Allow the platform to settle.
Result: The overload indicator lights are off
and the alarm does not sound. Proceed to
step 8.
Result: The overload indicator lights are
flashing at the platform and ground controls,
and the alarm is sounding. Repeat this
procedure beginning with step 5.
Note: There may be a 2 second delay before the
platform overload indicator light and alarm
responds.
8 Add an additional 10 lb / 4.5 kg test weight to
the platform.
Result: The overload indicator light is flashing
at both the ground and platform controls, and
the alarm is sounding. Proceed to step 9.
Result: The overload indicator light is off at
both the ground and platform controls, and
the alarm does not sound. Remove the
additional 10 lb / 4.5 kg test weight. Repeat
this procedure beginning with step 6.
Note: There may be a 2 second delay before the
platform overload indicator light and alarm
responds.
Summary of Contents for Genie Z-45/25 Bi-Energy
Page 71: ...July 2021 Service and Repair Manual Manifolds Part No 1312350GT Z 45 25 Z 45 25J 59 ...
Page 73: ...July 2021 Service and Repair Manual Manifolds Part No 1312350GT Z 45 25 Z 45 25J 61 ...
Page 80: ...Service and Repair Manual July 2021 Manifolds 68 Z 45 25 Z 45 25J Part No 1312350GT ...
Page 83: ...July 2021 Service and Repair Manual Manifolds Part No 1312350GT Z 45 25 Z 45 25J 71 ...
Page 119: ...July 2021 Service and Repair Manual 107 Electrical Schematic Options ...
Page 123: ...July 2021 Service and Repair Manual 111 Wiring Diagram 2 2kW Hydraulic Generator ...
Page 125: ...July 2021 Service and Repair Manual 113 Electrical Schematic Kubota D1105 ...
Page 128: ...Service and Repair Manual July 2021 116 Functions Electrical Schematic ...
Page 129: ...July 2021 Service and Repair Manual 117 Electrical Schematic Deutz D2 9 ...
Page 132: ...Service and Repair Manual July 2021 120 Deutz D2 9 L4 Engine Wire Harness ...
Page 133: ...July 2021 Service and Repair Manual 121 Electrical Schematic Deutz 2011 L03i ...
Page 136: ...Service and Repair Manual July 2021 124 Electrical Schematic Deutz D436 1 ...
Page 137: ...July 2021 Service and Repair Manual 125 Electrical Schematic Deutz D436 2 ...
Page 139: ...July 2021 Service and Repair Manual 127 Hydraulic Schematic 2WD Models ...
Page 143: ......