July 2021
Service and Repair Manual
Deutz D 2.9 L4 Engine Fault Codes
Part No. 1312350GT
Z
®
-45/25 • Z
®
-45/25J
91
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN FMI KWP
Description
654 3
583
Injector 4 (in firing order); short
circuit
654 4
589
High side to low side short circuit
in the injector 4 (in firing order)
654 5
571
Injector 4 (in firing order);
interruption of electric connection
676 11
543
Cold start aid relay error.
676 11
544
Cold start aid relay open load
677 3
956
Starter relay high side; short
circuit to battery
677 3
960
Starter relay low side; short
circuit to battery
677 4
957
Starter relay high side; short
circuit to ground
677 4
961
Starter relay low side; short
circuit to ground
677 5
958
Starter relay; no load error
677 12
959
Starter relay; powerstage over
temperature
703 3
426
Engine running lamp; short
circuit to battery
703 4
427
Engine running lamp; short
circuit to ground
703 5
424
Engine running lamp; open load
703 12
425
Engine running lamp;
powerstage over temperature
729 5
545
Cold start aid relay open load
729 12
547
Cold start aid relay; over
temperature error
898 9
305
Timeout Error of CAN-Receive-
Frame TSC1TE; Setpoint
1079 13
946
Sensor supply voltage monitor
1 error (ECU)
1080 13
947
Sensor supply voltage monitor
2 error (ECU)
SPN FMI KWP
Description
1109 2
121
Engine shut off demand ignored
1136 0
1398
Physikal range check high for
ECU temperature
1136 1
1399
Physikal range check low for
ECU temperature
1136 3
1400
Sensor error ECU temperature;
signal range check high
1136 4
1401
Sensor error ECU temperature;
signal range check low
1176 3
849
Sensor error pressure sensor
upstream turbine; signal range
check high
1176 4
850
Sensor error pressure sensor
downstream turbine; signal
range check high
1180 0
1193
Physical range check high for
exhaust gas temperature
upstream turbine
1180 0
1460
Turbocharger Wastegate CAN
feedback; warning threshold
exceeded
1180 0
1462
Exhaust gas temperature
upstream turbine; warning
threshold exceeded
1180 1
1194
Physical range check low for
exhaust gas temperature
upstream turbine
1180 1
1461
Turbocharger Wastegate CAN
feedback; shut off threshold
exceeded
1180 1
1463
Exhaust gas temperature
upstream turbine; shut off
threshold exceeded
1180 3
1067
Sensor error exhaust gas
temperature upstream turbine;
signal range check high
1180 11
1066
Sensor exhaust gas temperature
upstream turbine; plausibility
error
1188 2
1414
Wastegate; status message from
ECU missing
Summary of Contents for Genie Z-45/25 Bi-Energy
Page 71: ...July 2021 Service and Repair Manual Manifolds Part No 1312350GT Z 45 25 Z 45 25J 59 ...
Page 73: ...July 2021 Service and Repair Manual Manifolds Part No 1312350GT Z 45 25 Z 45 25J 61 ...
Page 80: ...Service and Repair Manual July 2021 Manifolds 68 Z 45 25 Z 45 25J Part No 1312350GT ...
Page 83: ...July 2021 Service and Repair Manual Manifolds Part No 1312350GT Z 45 25 Z 45 25J 71 ...
Page 119: ...July 2021 Service and Repair Manual 107 Electrical Schematic Options ...
Page 123: ...July 2021 Service and Repair Manual 111 Wiring Diagram 2 2kW Hydraulic Generator ...
Page 125: ...July 2021 Service and Repair Manual 113 Electrical Schematic Kubota D1105 ...
Page 128: ...Service and Repair Manual July 2021 116 Functions Electrical Schematic ...
Page 129: ...July 2021 Service and Repair Manual 117 Electrical Schematic Deutz D2 9 ...
Page 132: ...Service and Repair Manual July 2021 120 Deutz D2 9 L4 Engine Wire Harness ...
Page 133: ...July 2021 Service and Repair Manual 121 Electrical Schematic Deutz 2011 L03i ...
Page 136: ...Service and Repair Manual July 2021 124 Electrical Schematic Deutz D436 1 ...
Page 137: ...July 2021 Service and Repair Manual 125 Electrical Schematic Deutz D436 2 ...
Page 139: ...July 2021 Service and Repair Manual 127 Hydraulic Schematic 2WD Models ...
Page 143: ......