95
Error Source
Error Type
Condition
Solution
ID
Name
ID Name
212 Height sensor
12 Value too high
Output higher than
normal.
• Check wiring
• Check 5V supply voltage
• Shorted too high
• Replace sensor
14 Cross check fault
Height channels not
reading consistent or
correlated signals
• Check wiring
• Shorted to high or low
• Replace sensor
15 Value too low
Output lower than
normal.
• Check wiring
• Check 5V supply voltage
• Check ground
• Open or short circuit
• Replace sensor
16 Value at 0 V
Output at 0 volts.
• Check wiring
• Open circuit.
• Replace sensor
• Replace SCON
23 Too high
Outputs higher than
calibration point.
• Check height sensor for loose
or missing fasteners.
• Calibrate Sensor
24 Too low
Outputs lower than
calibration point.
• Check height sensor for loose
or missing fasteners
• Calibrate Sensor