Fault Codes
86
GR
™
-20J • GR
™
-26J
Part No. 1312899GT
Error Source
Error Type
Condition
Solution
ID
Name
ID
Name
01
Controller
interface
board
61
Joystick
Joystick is pushed when
machine is switching on.
Repair or replace the joystick.
62
Short-circuit on
function
switches
The function switch has
been closed for more than
2.5 seconds.
It should be possible to stop the
alarm by stopping the main
contactor or via the emergency
stop. If the problem persists, check
the wiring connection. If there is no
problem, the alarm is due to an
internal fault.
63
Battery out of
adjustment
The battery parameter
differs by more than 20%
from the nominal battery
voltage.
Check the battery type parameter.
64
Charge in
progress
The platform has been
started up with the battery
charger in operation.
If the alarm appears with the
charger disconnected from the
mains, there may be a problem
with the connection of terminal
A17. Otherwise, it is an internal
fault of the controller.
65
Value of angle
sensor incorrect
The value read by the
potentiometer is different
from the programmed value.
Check that the angle sensor
potentiometer is functioning
correctly. Otherwise, check the
wiring.
80
Lifting valve
There is a problem on one
of the following outputs:
terminal A32, terminal A26.
Check the condition of the valves
and their connections.
Otherwise, it is an internal fault of
the controller.
Summary of Contents for Genie GR-20J
Page 77: ...March 2022 Service Manual Function Manifold Part No 1312899GT GR 20J GR 26J 65 ...
Page 113: ...March 2022 Service Manual 101 Electrica l Schemati cs Electrical Schematic GRJ from GRJL 2298 ...
Page 116: ...Service Manual March 2022 104 Electrical Schematic GRJ from GRJL 2298 ...
Page 117: ...March 2022 Service Manual 105 GCON LED Panel GRJ from GRJL 2298 ...
Page 120: ...Service Manual March 2022 108 Temperature Sensor Harness GRJ from GRJL 2298 ...
Page 121: ...March 2022 Service Manual 109 Options GRJ from GRJL 2298 ...
Page 127: ......