Controller Movements - Mixing
Bucket
For all the telehandler models
Proceed as follow:
Set the Hydraulic Mixing Bucket Oil Direction
Switch A to position 0 and press the Mixing Bucket
Switch B to enable the movement of the internal
mixer of the bucket. Switch B has a block which
can be locked for continuous operation. Before
switching to another position, ensure the block is
unlocked at the top of switch B.
Setting switch A to position 2 or 1, regulates the
oil flow direction, to rotate the mixing blade either
clockwise or counterclowise.
To open the bucket door, set switch A to position
0 and press the Auxiliary Hydraulic Circuit Switch
C
. Then set switch A to position 1 or 2 to open or
close the bucket door.
To discharge the concrete, set switch A to position
0, set switch C to position 0, set switch A to
position 1 or 2, the mixer start to rotate clockwise
or counterclowise, pushing out the concrete.
For the use of this equipment and its remote
control, please read the specific manual
Operating Instructions
Phase
Switch Position
A
0
Stop Oil Flow
MIXING
B
1
Enable Mix.
Bucket Circuit
A
1 or 2
Rotate the Mix
OPEN
DOOR
A
0
Stop Oil Flow
C
1
Enable Mix.
Bucket Door
A
1 or 2
Open/Close
Bucket Door
A
0
Stop Oil Flow
DISCHARGE
C
0
Enable Mix. Blade
movements
A
1 or 2
Rotate Mix Blade