Service and Repair Manual
September 2021
Manifolds
56
Z®-30/20N • Z®-30/20N RJ •
Z®-34/22 • Z®-34/22N
Part No. 1268498GT
6 At the battery or coil terminals, reverse the
connections. Note and record the current
reading.
Result: Both current readings are greater than
0 mA and are different by a minimum of 20%.
The coil is good.
Result: If one or both of the current readings
are 0 mA, or if the two current readings do not
differ by a minimum of 20%, the coil and/or its
internal diode are faulty and the coil should be
replaced.
Summary of Contents for Genie 20N RJ
Page 83: ...September 2021 Service and Repair Manual 71 Power Cable Wiring Diagram ...
Page 86: ...Service and Repair Manual September 2021 74 Drive Contactor Panel Wiring Diagram ...
Page 87: ...September 2021 Service and Repair Manual 75 Manifold and Limit Switch Wiring Diagram ...
Page 90: ...Service and Repair Manual September 2021 78 LVI BCI Option Wiring Diagram ...
Page 91: ...September 2021 Service and Repair Manual 79 Charger Interlock Option ...
Page 94: ...Service and Repair Manual September 2021 82 CTE Option CE Models ...
Page 95: ...September 2021 Service and Repair Manual 83 Hydraulic Schematic ...
Page 117: ......