7 MAINTENANCE
88
7.17 Air Cleaner Removal / Inspection
The air cleaner is one of the most
important maintenance items on the
machine. Regular inspection and
replacement is necessary to ensure
proper performance and to prolong
engine life.
Inspect the air cleaner
elements daily.
If damaged or heavily
soiled, clean or replace the elements.
1.
Shut the machine down as described in section 5.13, then open the hood to
uncover the air cleaner acess door on rear of the left loader tower.
2.
Open the access cover, then pull the yellow slide lock (1) on the air cleaner
housing outward as shown. Next, turn the cover approximately 1/8 turn
CCW and pull to remove.
3.
Remove the primary element (2). The primary element can be cleaned and
reused up to five times, but should be changed at least once a year.
4.
Remove the secondary element (3). The secondary element is not
serviceable or washable. The secondary element should be replaced after
every three cleanings of the primary element.
2
1
3
7.17-1