Part No. 40462
DPL-25S • DPL-30S • DPL-25S Super Series
7 - 23
September 2016
Section 7 - Repair Procedures
PLATFORM
How to Test Power-to-Platform
GFCI outlet
1 Fully lower the platform, turn the key switch off.
2
AC and DC models
: Be sure the AC power
supply is properly connected.
3 Connect an AC voltage tester or a small hand
tool to the platform GFCI receptacle.
4 Test the voltage or test the hand tool operation.
Result: The voltage should be 115V AC nominal
or the hand tool should operate normally.
5 Push the black TEST button on the GFCI
receptacle.
Result: The voltage should be 0V or the hand
tool should not operate.
6 Push the red RESET button on the GFCI
receptacle.
Result: The voltage should be 115V AC nominal
or the hand tool should operate normally.