XM158 V1.0-NR
19
0-191
Frost 0~100%
192-223
Pulse opening fast to slow
224-254
Pulse closing slow to fast
255
100% Frost
Channel 14– Lamp on/off, reset, internal programs:
0-19
Color&Gobo change normal
20-29
Color change to any position
30-39
Color&Gobo change to any position
40-59
Lamp on
60-79
Lamp switch off
80-84
All motor reset
85-87
Scan motor reset
88-90
Colors motor reset
91-93
Gobo motor reset
94-96
Shutter & Dimmer motor reset
97-99
Other mo reset
100-119
Internal program 1 (secne1~8 of EEPROM)
120-139
Internal program 2 (secne9~16 of EEPROM)
140-159
Internal program 3 (secne17~24 of EEPROM)
160-179
Internal program 4 (secne25~32 of EEPROM)
180-199
Internal program 5 (secne33~40 of EEPROM)
200-219
Internal program 6 (secne41~48 of EEPROM)
220-239
Internal program 7 (secne49~56 of EEPROM)
240-255
Music Control (secne of Program 1)
Channel 15 – Pan fine 16bit
Channel 16– Tilt fine 16bit
ERROR CODES:
When you turn on the fixture, it will make a reset first. The display may show “XXer” while there are problems
with one or more channels. “XX” stands for channel 1,2,3,4,5,6,8,9 who has the testing sensor for position.
For example, when the display shows “01Er”, it means there is some error in channel 1. If there are some errors on
channel 1, channel 5, channel 6 at the same time, you may see the error message “01Er”, “05Er”,”06Er” flash
repeated for 5 times, and then the fixture will generate a reset signal, all the stepper reset. If the fixture remain error
message after performing reset more than 3 times, it will detect whether the fixture has more than 3 errors. If the
fixture has more than 3 errors (including 3 errors), all the channels can not work properly; but if the fixture has less
than 3 errors, only the channels which have errors can not work properly, others can work as usual.
Color-wheel error:
This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunctions (sensor failed or
magnet missing) or the stepping-motor is defective (or its drive circuit on the main PCB). The color wheel is not
located in the default position after the reset.