XM762-V1.0-NR
33
60-79
Lamp switch off
80-84
All motor reset
85-87
Scan motor reset
88-90
Colors motor reset
91-93 Gobo
motor
reset
94-96
Shutter & Dimmer motor reset
97-99
Other motor reset
100-119 Internal program 1 (secne1~8 of EEPROM)
120-139 Internal program 2 (secne9~16 of EEPROM)
140-159 Internal program 3 (secne17~24 of EEPROM)
160-179 Internal program 4 (secne25~32 of EEPROM)
180-199 Internal program 5 (secne33~40 of EEPROM)
200-219 Internal program 6 (secne41~48 of EEPROM)
220-239 Internal program 7 (secne49~56 of EEPROM)
240-255 Music Control (secne of Program 1)
Pan Fine 16bit
22
2
0-255
Fine control of Pan movement
Tilt Fine 16bit
23
4
0-255
Fine control of Tilt movement
11. ERROR MESSAGE
When you turn on the fixture, it will make a reset at first. The display may show“Err channel is
XX” while there are problems with one or more channels. “XX” stands for channel 1, 2, 3, 4, 5,
6 who has the testing sensor for positioning. For example, when the display shows “Err channel is
Color wheel”, it means there is some error in channel 4. If there are some errors on channel 4,
channel 5, channel 6 at the same time, you may see the error message “Err channel is Color
wheel”, “Err channel is Pan movement”, “Err channel is Tilt movement” flash repeated for 2
times, and then the fixture will generate a second reset. If the fixture remain error message after
performing reset more than 2 times, only the channels which have errors can not work properly,
others can work as usual. Please contact with dealer or manufacturer for service, self repair is not
allowed.
PAN- movement Er
(PAN-yoke movement error) This message will appear after the reset of the fixture if the yoke’s
magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is
defective (or its driving IC on the main PCB). The PAN-
movement is not located in the default
position after the reset.
TILT- movement Er
(TILT-head movement error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor
is defective (or its driving IC on the main PCB). The TILT-
movement is not located in the default
position after the reset.