background image

2

2

LIVE

NEUTRAL

GROUND

BLACK

WHITE

RED

FF

 x1

Wall plate

Plaque murale

Placa de pared

Model / Model / Modelo #:

 SE1303-WH3-00LFW-G, SE1303-BP2-00LFW-G  

OUTDOOR LED SMART SECURITY LIGHT

 (Page 1)

LAMPE DE SÉCURITÉ INTELLIGENTE À DEL POUR L’EXTÉRIEUR

 (Page 3)

LUZ DE SEGURIDAD LED INTELIGENTE PARA EXTERIORES 

(Página 6)

Diffuser

Diffuseur

Difusor

Required/ 

Nécessaire/ 

Se necesita

* Actual hardware may differ from illustration/ * Les éléments de fixation réels peuvent être différents de ceux de l’illustration./  * Es posible que los herrajes reales difieran de los de la ilustración.

INSTALLATION FOR ROUND SURFACE

MOUNT ELECTRICAL BOXES

INSTALLATION FOR RECESSED

ELECTRICAL BOXES

x2

AA/BB

DD x1

EE x1

GND

FRON

T

x2

AA/BB

DD x1

GND

FRON

T

GND

FRON

T

GND

FRON

T

1 RECESSED

1 SURFACE

Pull supply wires out of the junction box (j-box). With the side marked “FRONT” facing out, attach the mounting strap 

(DD)

 to the j-box with 

machine screws (

AA

 or 

BB)

. Remove the protective liner from adhesive side of the gasket 

(EE)

. Guide the j-box wires through the gasket 

opening. Aligning the center holes of the gasket and mounting strap and apply the gasket to the outer edge of round edge of the j-box.
Pull supply wires out of the junction box (j-box). With the side marked “FRONT” facing out, attach the mounting strap (

DD)

 to the j-box with 

machine screws 

(AA or BB)

Motion Sensor (PIR) Head

Tête du détecteur de mouvement 

passif à infrarouge (PIR)

Cabeza del sensor de movimiento (PIR)

Pairing Button

Bouton d’appariement

Botón de emparejamiento

Lower Motion Sensor

Détecteur de mouvement inférieur

Sensor de movimiento inferior

Light head

Tête de la lampe

Cabeza de luz

SHUT OFF POWER AT THE CIRCUIT BREAKER OR FUSE PANEL BEFORE REMOVING

 THE OLD FIXTURE OR INSTALLING THE NEW ONE.

ENGLISH

WARNINGS AND CAUTIONS

HOW TO CHOOSE A LOCATION SITE

IMPORTANT!! READ BEFORE YOU BEGIN!

Select a location that allows the sensor to perform to its highest level.
The fixture can be mounted three distinct ways: 

WALL MOUNT

EAVE MOUNT 

or

 BOX 

MOUNT

.

This security light uses passive infrared (PIR) technology to automatically turn on the light. 

Passive infrared does not detect motion, but sensing differences in ambient temperatures, 

versus warmer objects in its field of view. As such, the sensor can be set off by a variety of 

other sources, including dryer vents, hot tubs, and the like. The PIR sensor cannot detect 

motion through plexiglass or glass barriers. Select an installation location carefully. Do not 

aim the PIR towards areas having frequent pedestrian or motorized traffic, and/or other 

objects that generate areas of warmer air. All of these may trigger the motion sensor security 

light and maybe disruptive to the intended operation of the light.

Do 

NOT

 install near other sources of light, which can fool the built-in light sensor into thinking 

it is daylight, and may prevent the proper operation of the light.

3

4

3

2

1

READ ENTIRE INSTALLATION PROCEDURE BEFORE YOU BEGIN!

1. This fixture can only be installed over a recessed electrical box, 

OR

 a UL Listed  

  surface mount electrical box rated for wet locations. Surface mount electrical  

  boxes require the use of the foam gasket (included), to prevent water seeping into  

  the electrical box.   

2. Do not look directly at LEDs for extended period of time. Can cause eye damage. 

3. LEDs can be damaged by electrostatic discharge shock. Before installation,

  discharge yourself by touching a grounded bare metal surface to remove this  

  hazard.   

1 SURFACE

 

1 RECESSED  

WALL MOUNT EAVE MOUNT BOX MOUNT

INSTALLATION

SHUT OFF POWER BEFORE REMOVING OR INSTALLING ANY FIXTURE.

The fixture can be mounted to a round surface mount or a recessed electrical box.

WARNING!

Recommended Mounting Height: 7-15 ft.

Minimum Mounting Height: 7 ft.

NOTE:

 Mounting the fixture above the 7-15 ft. range 

can result in a decrease in the sensor detection range.

1

GND

FRONT

CC

x1

AA

x2

BB

x2

EE

 x1

FF

 x1

DD

x1

4. Minimum 90°C supply conductors. For fixture electrical ratings, see fixture label.  

5. If unsure if the electrical box is properly grounded, or the box is plastic and has

  no ground wire, or are unfamiliar with the methods of properly grounding fixture,  

  consult a qualified electrician.

6. Do 

NOT

 use this fixture with dimmers.

7. Fixture will reliably operate between temperatures from -20°F to 122°F. 

  (At temperatures above 92°F, the PIR may not detect body heat.)

Push the ends of the house wires from the J-box into the contact holes of 

the electrical disconnect-plug from the hardware kit

 (FF)

, carefully match 

the color of the black and white wires corresponding to the color coded 

surface of the connector. Insert the house ground wire into the hole marked 

by the red surface. Verify the wires are secure. 

Electrical disconnect plug

Fiche de déconnexion électrique

Enchufe de desconexión eléctrica

Hardware kit* / Kit de petit 

matériel de fixation*/ 

Kit de aditamentos*

Summary of Contents for SE1303-WH3-00LFW-G

Page 1: ...he like The PIR sensor cannot detect motion through plexiglass or glass barriers Select an installation location carefully Do not aim the PIR towards areas having frequent pedestrian or motorized traf...

Page 2: ...light fixture product The manufacturer will not be liable for any other loss damage labor costs or injury which is caused by the product This limitation upon the liability of the manufacturer include...

Page 3: ...ER 1 Ce luminaire ne peut tre install que sur un coffret lectrique encastr OU sur un coffret lectrique montage en surface homologu UL pour les endroits tr s humides Les coffrets lectriques montage en...

Page 4: ...montage en surface rond ou un coffret lectrique encastr SOUS TENSION NEUTRE TERRE NOIR BLANC ROUGE 1 ENCASTR Tirez sur les fils d alimentation pour les faire sortir de la bo te de jonction j box Posit...

Page 5: ...n avec la vente l utilisation ou la r paration du produit Cette garantie vous conf re des droits particuliers et vous pouvez galement avoir d autres droits en fonction de l tat ou de la province o vou...

Page 6: ...uro si la caja el ctrica est conectada a tierra adecuadamente o si la caja es de pl stico y no tiene cable de conexi n a tierra o si usted no est familiarizado con los m todos para conectar adecuadame...

Page 7: ...mpra Llame al 1 800 291 8838 para obtener un n mero de autorizaci n de devoluci n y una direcci n a la que enviar su producto defectuoso Nota NO se aceptar n env os contra reembolso C O D La responsab...

Page 8: ...guraci n de control 24 7 1 Es posible que el sensor sea activado por un animal peque o o un autom vil que pasa 2 Es posible que aire caliente respiradero de secadora escape de auto etc est activando e...

Reviews: