![Terbly G6H NOVA User Manual Download Page 11](http://html.mh-extra.com/html/terbly/g6h-nova/g6h-nova_user-manual_1088589011.webp)
G6H NOVA User Manual XM1557-V1.1-NR
10
3) Replace lamp and make it stable
.
Please be noted that there's only one installation
direction for the lamp
.
Make sure the replaced lamp has the same installation direction
with the old one
.
Once again
make sure it’s stable
.
4) Put on the plate of lamp socket and tighten screw A
B
C
.
5) Please reset the lamp life-time
.
Otherwise it is likely to trigger the protecting firmware
of system to make the replaced lamp close itself automatically
.
Please remember the lamp is not a hot-restrike type
you must wait for approximately 10
minutes after having turned off the lamp before you can turn it back on again
.
CAUTION!
DO NOT OPERATE THIS DEVICE WITH OPEN COVER
5.2. RIGGING THE DEVICE
CAUTION!
PLEASE CONSIDER THE GB7000.1-2015, GB7000.217-2008 AND THE OTHER
RESPECTIVE NATIONAL NORMS DURING THE INSTALLATION. THE
INSTALLATION MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON.
The structure on which the device is rigged must be able to support 10 times the weight of
the device for 1 hour without any critical deformation occurring.
The installation must always be secured with a secondary safety attachment, e.g. the
included appropriate safety cable.
Never stand directly below the device when rigging, de-rigging or maintaining the device.
All electrical connections should be approved by a qualified electrician prior to using the
product.
When the device is permanently installed these installations have to be approved by a
qualified person once a year.
Overhead rigging requires extensive experience, including (but not limited to) calculating
working load limits, specifying installation/ rigging materials, and periodic safety
inspection of all installation material as well as the device. If you lack these qualifications,
do not attempt the rigging of this device yourself. Improper installation/ rigging can result
in serious bodily injury.
Before rigging make sure that the installation area can hold a minimum point load of 10
times the device’s weight.