![Terbly G6H NOVA User Manual Download Page 10](http://html.mh-extra.com/html/terbly/g6h-nova/g6h-nova_user-manual_1088589010.webp)
G6H NOVA User Manual XM1557-V1.1-NR
9
5. INSTALLATION INSTRUCTIONS
5.1. INSTALLING OR REPLACING THE LAMP
CAUTION!
ONLY INSTALL THE LAMP WITH THE DEVICE UNPLUGGED FROM THE
MAINS
CAUTION!
THE LAMP HAS TO BE REPLACED WHEN IT IS DAMAGED OR DEFORMED
Lamp must be replaced between 2000-6000 hours based on usage as indicated on display
.
Use
only genuine original Philips Platinum Flex lamps
.
Other lamp brands may cause damage and
void the warranty
.
Before replacing the lamp let the lamp cool down
because during operation
the lamp can
reach very high temperature
.
During the installation of HID lamps do not touch the glass bulbs bare handed. Always use a
gloves or a cloth to handle the lamps during insertion and removal
.
Do not install lamps with a higher wattage
.
They generate higher temperatures than which the
device was designed for
.
WARNING!
THE BULB SHOULD BE REPLACED WHEN DAMAGED OR HEAT
DISTORTION
.
CAUTION!
DISCONNECT THE FIXTURE FROM POWER AND ALLOW IT TO COOL FOR
TEN MIN
Procedures
1) Please put the fixture on a smooth desk release the screw A B C
.
Then open the plate
for lamp-socket
.
2) Before taking off the lamp
please release the two red wires which connect to the lamp
.
Then take off the plate of the lamp carefully
please press the lamp and cover for
lamp-socket
.
Make sure remove the lamp from left to right until the lamp is took off
.
Attention wrap
the lamp with soft cloth which go with the lamp to avoid your finger touching the glass of
lamp directly
.