![TeraBee TeraRanger Evo Swipe Plus User Manual Download Page 28](http://html1.mh-extra.com/html/terabee/teraranger-evo-swipe-plus/teraranger-evo-swipe-plus_user-manual_1088208028.webp)
2 bytes
2 bytes
“PD”
2 bytes
PD max range thresholds (millimeters)
2 bytes
PD time thresholds (millisecond)
2 bytes
“ET”
2 bytes
range trigger
(millimeters)
2 bytes
engagement time
(seconds)
1 byte
disengagement time
(seconds)
1 byte
“GR”
2 bytes
swipe minimum
thresholds
(millimeters)
2 bytes
swipe maximum
thresholds
(millimeters)
2 bytes
validation range
thresholds
(millimeters)
2 bytes
validation time
thresholds
(milliseconds)
2 bytes
CRC
1 byte
5.5.6.2.
Text Frame
This command provides users with all parameter values in text form and returns the
following frames:
BPTD: max range thresholds: xxxx [mm]<\n> PD: max range thresholds: xxxx [mm]
time thresholds: x.xxxxxx [s]<\n>ET: range trigger: xxxx [mm] engagement time: x [s]
disengagement time: x [s]<\n>GR: swipe minimum thresholds: xxxx [mm] swipe
maximum thresholds: xxxx [mm] validation range thresholds: xxxx [mm] validation time
thresholds: x.xxxxxx [s]<\n>
Copyright
©
Terabee 2020
Terabee, 90 Rue Henri Fabre
01630, St Genis-Pouilly, France (next to CERN)
28/29