TERABEAM Marquee EX User Manual Download Page 18

 

 

Marquee™ Point-to-Point Series User Guide 

Section 3    

Configuration 

3.1 

Installing the Management Software 

The Windows-based Configurator software can be installed on a laptop or PC running Windows 98, ME, 
2000, NT, or XP.  This software has a GUI (Graphical User Interface), which makes it easy to use.  The 
program allows you to locally or remotely perform the following procedures: 
 

its running on the network 

e current configuration of the units 

 

Load and save configurations 

 

Update the firmware of the units 

 

Note:

 

Prior to installing a newer version of the Configurator program, you will need to remove any 
older versions: 

1. Under 

the 

Start

 button on your desktop, go to 

Settings

2. Click 

on 

Control Panel

3. Choose 

Add/Remove Programs

4. Select 

Configurator

5.  The software will uninstall itself. 

 

Windows Installation – 

To install the Configurator in Windows, perform the following steps: 

1.  Insert the CD-ROM included in the Marquee kit

 

into the appropriate drive of your computer.  Using 

you

y: 

\Management Software\Configurator

. Run the Configurator Installation program (the 

.exe

 file). 

2.  The InstallShield runs. Follow the onscreen instructions to install the Configurator. If you are installing 

the

u are 

upgrading from a previous installation, your files will be stored in the directory where you last saved 
the Configurator files. The InstallShiel

urato

sktop. 

 
3. The 

InstallShield Wiza

cate successful installation of the 

Configurato

 

to complete the installation. 

3.2 

After 

igurator installation, you 

gure your M

following steps provide a quick pro

started. For m

th information about the 

Configurator and its commands, menus, and option

se refe

figuration 

Guide

, available as a pdf file on your CD ROM. Also, an onlin

p is available by pressing 

F1

 or clicking 

Hel

 

IMPORTANT: 

Your Ma

st be on the same sub

here the Configurator 

ve a routable IP address, in ord

ou 

will get a status of Offline for the units (see the Status
LEDs show activity. In order to be able to configure the units, change the IP address of 
your computer to a 198.17.74.x sub-net (the Marquee’s default sub-net configured from 
factory). Once you have access to the units, you can assign a new IP address to them 

Setup

 tab and 

IP Host 

button.

 

 

Display a list of un

 

Display and edit th

r Windows Explorer open the contents of the CD-ROM drive and select the following director

 

 program for the first time, files are stored in the directory 

\Program Files\Configurator

. If yo

d also installs shortcuts to the Config

r on your de

rd Completed

 screen will appear to indi

r.  Click 

Finish

Using the Configurator 

completing the Conf

arquee system. The 

are ready to confi

cedure to get you 

ore in-dep

r to the 

Marquee Series Con

s plea

e hel

p-> Index

 from the main screen. 

rquee units mu

net as the computer w

er to access them. If not, y

 column in Figure 3.1) even if the 

program is installed, or ha

later by clicking on the 

Version 1.2 

Page 15 

February 2005 

Summary of Contents for Marquee EX

Page 1: ...e Point to Point Series User Guide Contact Terabeam www terabeam com 8000 Lee Highway Falls Church VA 22042 Office 703 205 0600 Fax 703 205 0610 Sales 1 888 297 9090 MNL 500274 001 Version 1 2 Februar...

Page 2: ...ther rights that vary from state to state This warranty is only extended to purchases made in the United States of America or its possessions SPECIAL WARRANTY NOTICE The warranty is null and void if a...

Page 3: ...tor 15 3 3 Configuring the Marquee 16 Appendix A Marquee Technical Specifications 19 2005 Terabeam Wireless All Rights Reserved No part or parts of this document may be reproduced translated stored in...

Page 4: ...ures 1 1a and b The FP enclosure features a 23 dBi integrated antenna The EX enclosure comes either with a 23 dBi flat panel antenna attached to the top of the unit or it has an N type connector on th...

Page 5: ...VAC to 48 VDC power supply two each CD ROM with Windows based Configurator software User s Manual A Terabeam outdoor Ethernet cable must be ordered separately per unit Available lengths are 50 100 20...

Page 6: ...network that resembles your actual configuration as close as possible By using such a mock up troubleshooting potential problems will be much easier than if you already installed the equipment in the...

Page 7: ...daptor bracket B a pole clamp C and a U bolt D Figure 2 2 shows the hardware provided to mount the Marquee FP unit Pole Clamp C U Bolt D Pivot Adaptor Bracket B Pole Mounting Bracket A he integrated a...

Page 8: ...ion the bracket so that the side that has the circular tab is pointing towards the center of the unit Secure to the unit by threading two nuts and tighten them firmly with an appropriate wrench 2 Atta...

Page 9: ...be properly water proofed with all weather electrical tape Permagum or equivalent Do not use Silicon glue The Marquee EX unit is installed by using an X shaped adaptor bracket A that is secured to the...

Page 10: ...hing connected to the jack may result in damage to the TX section of the unit which will not be covered by the factory warranty and will be a billable repair 1 Fit the adaptor bracket A to the four st...

Page 11: ...the unit making sure the notch on the connector is correctly aligned with the tab on the jack as shown on Figure 2 10 Turn the round locking nut clockwise as you push in until it securely fastens onto...

Page 12: ...5 DC Powe Protecte If you are using a Marquee unit with an external antenna connect the antenna to the N type female jack on the back of the unit RJ 45 Ethernet Connector To Switch Router or PC To Ma...

Page 13: ...isplayed of the power supply to the DC Power jack on the Cat 5 DC Power pply into an AC outlet Check that the red Power LED on the Marquee r the wireless medium the green Wireless Link LED should be f...

Page 14: ...Marquee in onto the local unit Fig 2 13 Click the Analyze tab then click the Wireless Link Test button Enter IP Address window appe 3 Log The ars Fig 2 14 The IP address and the password should be e c...

Page 15: ...lick the Link Test button or double click the partner unit The Remote Test Li 16 The main goal now is to peak the SNR levels at both ends of the link Figure 2 15 Select a Remote Link Partner Screen 4...

Page 16: ...weep in both azimuth and elevation is made in order to identify these false peak SNR readings so to zero in on the true peak alignment reading due to the main antenna beam 10 Tighten the two Azimuth a...

Page 17: ...Line of Sight Adjustment for Signal Optimization EX Enclosure Rotate in this plane for azimuth alignment Rotate in this plane for elevation alignment Elevation adjustment bolt Azimuth adjustment bolt...

Page 18: ...3 The InstallShield Wiza cate successful installation of the Configurato to complete the installation 3 2 After igurator installation you gure your M following steps provide a quick pro started For m...

Page 19: ...this button 5 afe place onfigured for operation Marquee Bridge P P 2 each The default read write password is public S IP addresses Read Write password Radio frequency channel 1 Co t a crossover Ether...

Page 20: ...Click on Setup 2 The IEEE 802 11 Setup screen appears see Figure 3 5 Select the type of Station this Marquee is going to be In a P P configuration one unit must be Base and the other must be 9 Click...

Page 21: ...value Click OK Figure 3 7 TurboCell Advanced Setup Screen Figure 3 8 System Access Setup Network ID 1 from 0 through 15 to identify your network Both units in a link must be configured with the same...

Page 22: ...tomatic channel searching CPEs Yes Encryption DES 56 bit Blowfish 128 bit AES 128 Bit Upgradeable Q4 04 Note Encryption option lowers throughput since it is done in software Watchdog Reboot Timer Yes...

Page 23: ...389 x 389 x 29 mm EX E x 3 25 in 305 x 356 x 83 mm nclosure 15 nclosure 12 x 14 nclosure 2 90 lbs 1 32 Kg nclosure 9 65 lbs 4 38 Kg or all weather LED status indicators Pow ireless Link and Ethernet...

Page 24: ...ivity3 7 8 4 dB 3 dB ve Level 30 dB Over The Air D U tab p to 54 M ctab PSK sion for s for a 3 6 Versio Thro r s e channel Modulation Scheme OFDM SK Radio Operation Time Duplex TDD Time Division Duple...

Reviews: