6. Warranty

 

 
We provide 24 month warranty from date of receiving the unit, if the unit was handled properly. 
The damage of the NiMH-battery caused by improper handling as well as mechanical damage on the unit 
are excluded from warranty. Warranty is not provided, if the housing was opened.

 

 
 
 
 

7. Safety 

Advice 

 

The measurement unit is not approved for the use in explosive areas! 
The unit is not  approved for the use in power utilities! 
Only measurements can be executed at voltage-free objects.  

 
 
 
 

8. Specifications 

 

Housing 

 

: Plastic Housing 200 mm x 100 mm x 40 mm (L x B x H) 

Weight   

 

: app. 350 g 

Display   

 

: alphanumeric Display, 1 line with 16 Letters, 

 

 

  

  Display field 60 mm x 15 mm  

Measure Ranges 

: Resistor 

20 k

 - 2.0 T

 Tolerance ± 1xEXX 

 

PC - Interface   

: serial Interface, 9-pin SUB-D - Connector 

PC - Software   

: Excel – Software for Data transmitting and remote control

 

Battery   

 

: NiMH 9V / 160 mAh to IEC 6 F 22 

 

  

 

  Operating time of completely loaded battery: approximately 1 hours of  

 

  

 

  continuous operation 

 

 

  

 

  Charge time with enclosed power adapter: maximum 14 hours  

Power Supply   

: 9V-DC / 300 mA 

 
 
 
 

9. 

Parts of Delivery  

 

• 

Tera – Ohmmeter TOM 584 

• 

9V NiMH - Battery 

• 

Plug Power supply  9V-DC / 300mA 

• 

2 pce. Teflon insulated measurement lead, 1m 

• 

1 groundig cable with aligator clip 

• 

Serial PC - Cable 9 pol. 

• 

3,5“ Disk with PC - Software 

• 

Foam Packing 

• 

 Operating Instructions 

• 

 Certificate of factory calibration 

Summary of Contents for TOM 584

Page 1: ...TF The TERA Ohmmeter TOM 584 works with the Current Voltage Measurement This is the inexpensive version of the TOM 374 High resistances up to 2x1012 Ohm 2 Tera Ohm can be measured with 100 volts and...

Page 2: ...Set Up Functions 5 3 1 Timer 6 4 Other Display Information s 6 4 1 Display Contrast 6 5 PC Operating 6 5 1 System requirements 6 5 2 Softwareinstallation 6 5 3 Starting the Software 7 5 4 Software Ma...

Page 3: ...ith 1200 V and then measured the discharge time in an ionization air The start and stop voltage can be selected The pos and neg discharge time as well as the offset voltage will be shown in the displa...

Page 4: ...vered with a 9V NiMH Battery and is directly ready to start Only the enclosed plug power supply should be used for charging the battery and stationary work The electrodes are connected to the correspo...

Page 5: ...me and in the display appears AVERAGE LAPSE By pressing key A the middle value over the measure time will be displayed AVERAGE By pressing key B the last value after the end of the measure time will b...

Page 6: ...t can quietly be completed If the Battery Voltage is lower as 7 0 volts following display appear one after the other Then the unit automatically switches off to avoid a destroying of low Voltage of th...

Page 7: ...EPROM Start Measurement With Enter the count down timer for the measurement cycle will be started After the count down timer returned to zero it is possible to store the complete measurement curve 100...

Page 8: ...ght app 350 g Display alphanumeric Display 1 line with 16 Letters Display field 60 mm x 15 mm Measure Ranges Resistor 20 k 2 0 T Tolerance 1xEXX PC Interface serial Interface 9 pin SUB D Connector PC...

Page 9: ...EOS ESD S 11 11 DIN EN 61340 5 1 2 3 comprising to the measurement of transit and surface resistances 1 shielded and 1 no shielded Measure cord Other electrodes are available on inquiry Info Make sure...

Page 10: ...10 12 Legend 1 Power Supply connector 9 12V DC 2 Serial PC Interface 3 Measure Voltage Output 4 Measure Input 5 Contrast Potentiometer for the LC Display 6 Ground connector...

Page 11: ...ezieht die Forderung der EWG Richtlinie ber die elektromagnetische Vertr glichkeit Richtlinie des Rates vom 3 5 1989 89 336 Stand Juli 1993 erf llt insbesondere der Normen EN 61010 Safety EN 55011 Gru...

Reviews: