Number of External Temperature Probes:

 

a) DLT-10-Pt

 

b)  DLT-10-2Pt

 

1

 

2

 

Sensor Type of External Temperature

 

Probes

 

Pt1000

 

Temperature Range measured by External Probe,º С 

 

-

50…+250*

 

Probe connection cable length, m, max

 

2

 

Absolute Accuracy of temperature measurement by External 
Probe, %

 

±0,4+0,002|t|

**

 

Records in the Memory:

 

а) 

DLT-10-Pt

 

b)  DLT-10-2Pt

 

2621440

 

1966080

 

      * The operating range is determined by the design of external probe

 

     ** In set with external Probe

 

 

 

Table 1.3 

– Specifications of DLT-11 Data Logger

  

Characteristic

 

Value

 

Humidity Measurement Range Rh, % (without condensation)

 

0…100

 

Temperature Range,º С

 

-

30…+60

 

Basic Absolute Accuracy of temperature measurement by 
Internal Sensor, 

о

С

 

±0,5

 

Temperature Resolution, ºС

 

0.1

 

Basic Absolute Humidity Accuracy, %:

 

a) in the range (0…10) %

 

  

b) in the range (10…90) %

 

  

c) in the range (90…100) %

 

 

±4

 

±3

 

±4

 

Humidity Resolution, %

 

1

 

Internal Sensor Response Time (63%), min:

 

а) Humidity

 

б) Temperature

 

15

 

12

 

Records in the Memory, no less

 

2621440

 

 

Table 1.4 - Specifications of DLT-11-Pt, DLT-11-2Pt Data Loggers 

 

Characteristic

 

Value

 

Humidity Measurement Range, %

 

(without condensation)

 

0…100

 

Temperature Range measured by Internal Sensor,º С

 

-

30…+60

 

Basic Absolute Accuracy of temperature measurement by 
Internal Sensor, 

о

С

 

±0,5

 

Temperature Resolution of Internal Sensor, ºС

 

0.1

 

Basic Absolute Humidity Accuracy, %:

 

a) in the range (0…10) %

 

  

b) in the range (10…90) %

 

  

c) in the range (90…100) %

 

 

±4

 

±3

 

±4

 

Humidity Resolution,%

 

1

 

Internal Sensor Response Time (63%), min:

 

а) Humidity

 

б) Temperature

 

15

 

12

 

Summary of Contents for DLT-10

Page 1: ...A 2 046 09728 16 Dated 21 04 2016 DLT 10 11 DATA LOGGER DLT 10 Pt DLT 10 2Pt DLT 11 Pt DLT 11 2Pt User s Manual PJSC ER 7 Vsikhsvyatska str 14030 Chernihiv Ukraine 38 0462 606 740 606 840 e mail info...

Page 2: ...ER SETUP 10 2 1 Logging Interval 10 2 2 Logging Modes 10 2 3 Options for starting Logging 10 2 4 Delayed Start 11 2 5 Alarm Processing 11 2 6 Alarm Conditions 11 2 7 High Low Limits Alarm Settings 11...

Page 3: ...Logging Interval sec 60 3600 Interface for PC Connecting USB 2 0 Activation and Operating Mode Indication OLED Display Battery Life in normal conditions with logging interval more than 60 sec without...

Page 4: ...racy of temperature measurement by Internal Sensor 0 5 Temperature Resolution 0 1 Basic Absolute Humidity Accuracy a in the range 0 10 b in the range 10 90 c in the range 90 100 4 3 4 Humidity Resolut...

Page 5: ...ement with the customer Main Specifications of External Probe is set in its passport In set with external Probe 1 2 2 Data Logger is intended for use in the following conditions Ambient temperature fr...

Page 6: ...e 1 External Temperature Probe 2 Humidity Sensor DLT 10 DLT 10 Pt DLT 10 2Pt DLT 11 DLT 11 Pt DLT 11 2Pt 1 6 Control Functions and Indication 1 6 1 Two control buttons serve to control the modes of th...

Page 7: ...Start Stop Short OK button push then long ALARM button push Alarm ON OFF 1 6 3 Data Logger status The main screen Figure 3 contains the status bar of the logger in which the following icons can be pr...

Page 8: ...pages The second page automatically shows after 3 seconds When calling indication the data logger makes measurement regardless of the logging state These results are not recorded in the archive When...

Page 9: ...on screen Figure 7 contains the serial number of the logger SN the logger label LB and the software version ver Figure 7 Service Information Screen When starting logging by button manual start up of t...

Page 10: ...ons Below are the features of the Data Logger setup not marked in Logger soft User s Manual 2 1 Logging Interval Valid Logging Interval limits are from 1 to 60 minutes The list of valid values 1 min 2...

Page 11: ...ns Data Logger has three types of alarm conditions DISABLED HIGH LOW MULTILEVEL Only for internal temperature channel ATTENTION The alarm can only be reset using the reconfiguration 2 7 High Low Limit...

Page 12: ...the logger screen short logging interval 3 2 Table 4 shows the predicted operating time of Data Logger at different temperatures with different logging intervals without activated indication and with...

Page 13: ...Logger for measuring Relative Humidity of ambient air Dotted area is maximum permissible operating range of of Data Logger for measuring Relative Humidity of ambient air In case Data Logger operate o...

Page 14: ...elative humidity less than 98 non condensing 10 2 Data Logger in its original packaging is transported by all types of covered vehicles in accordance with the shipping rules valid for this type of tra...

Reviews: