1.7 Connection to PC
Connecting Data logger to the PC is possible in the COM Port mode or in the
Fash Drive mode.
The COM Port mode allows to configure the logger and download the stored
data using
LoggerSoft
PC software.
To do this, press the
OK
button and within 5 seconds connect the logger to
the PC USB-port. In this mode the logger display is shown in the
Figure 4.
In the Flash Drive mode, the logger generates PDF or CSV report available
for downloading to the PC. To do this, connect the logger to the PC USB-port. The
minimum report generation time is 30 seconds. During this time disconnecting the
logger from the PC is not recommended. In this mode the logger display is shown
in the Figures 5a, 5b.
2 DATA LOGGER SETUP
Data Logger is set up with the help of
LoggerSoft
PC software. Follow
User's Manual
,
Data Logger Setup
,
Data Logger Setting
s. Starting Data Logger
can be done either during setup or by pressing the buttons. Below are the features
of the Data Logger setup, not marked in
Logger soft, User's Manual
.
2.1 Logging Interval
Valid Logging Interval limits are from 1 to 60 minutes.
The list of valid values: 1 min; 2 min; 3 min; 5 min; 10 min; 15 min; 20 min;
30 min; 60 min.
It’s important:
After changing the archiving period, the previous data is
overwritten.
2.2 Logging Modes
TILL THE MEMORY FULL. Logging starts from the launch moment and
stops after filling all the memory (from the start point). Restart logging is
only possible after re-configuration.
CYCLIC. Logging is continuous, cyclically wiping the oldest data with
new data.
2.3 Options for starting Logging
AFTER SETTING. Logging starts immediately after Data Logger setup
without user intervention.
BY BUTTON. Logging starts after pressing the button.
AT SPECIFIC TIME.
For options
After Setting
and
By Button
, the
Delayed Start
option is available
(see paragraph 2.4).
NOTE
:
Before selecting option for starting logging it is necessary to
synchronize time (
Logger soft, User's Manual, Data Logger Setup, Time
Synchronization
)
.
Important:
Performing the time synchronization stops the current logging.