USER MANUAL
-
31
-
YF-74L
A2
TROUBLESHOOTING AND FAULT FINDING
Notes: The following operations must be performed by qualified electricians with valid certifications. Before
maintenance, you are suggested to contact local distributor to verify qualification.
Malfunctions
and solutions of MIG 175GD:
Malfunctions
Solution
The meter show nothing;
Fan does not rotate;
No welding output
1.
Confirm the power switch is on.
2.
Power supply available for input cable.
3.
Check if the silicon bridge is damaged.
4.
There is malfunction occurs in the supplementary power
source on control board (contact dealers).
The meter shows;
Fan works normally;
No welding output
1. Check if all the sockets in the machine are connected well.
2. There is open circuit or badness of connect at the joint of output terminal.
3. The control cable on the torch is broken off or the switch is damaged.
4. The control circuit is damaged.(contact to dealers)
the meter shows;
Fan works normally;
Abnormal indicator lights.
1. It might be over-current protection, please turn off the power switch;
restart the machine after the abnormal indicator light winked.
2. It might be overheating protection, please wait for about 2-3 minutes until
the machine renew without turn off the power switch.
3. It might be multifunction of inverter circuit. (contact dealers)
Summary of Contents for MIG175GD
Page 1: ...USER MANUAL MIG175GD...
Page 2: ......
Page 14: ...USER MANUAL 12 YF 74L A2 Explanatory drawing for Installation of MIG 175GD MIG...
Page 15: ...USER MANUAL 13 YF 74L A2 Explanatory drawing for Installation of MIG 175GD LIFT TIG...
Page 16: ...USER MANUAL 14 YF 74L A2 Explanatory drawing for Installation of MIG 175GD STICK...
Page 27: ...USER MANUAL 25 YF 74L A2 STRUCTURE CHART AND MAJOR PARTS LIST Structure Chart of MIG175GD...