POTENTIAL OPERATING PROBLEMS
The phenomenon listed below may happen due to relevant accessories used, welding material, surroundings and power
supply. Pleas improve surroundings and avoid these problems..
A. Arc starting difficulty. Arc interruption happens easily:
1) Examine whether grounding wire clamp contacts with the work pieces well.
2) Examine whether each joint has improper contact.
B. The output current fails to reach rated value:
The deviation of power voltage from rated value may cause that the output current does no accord with adjusted value.
When the power voltage is lower than rated value, the maximum output current may be lower than rated value.
C. The current can not keep stable during operation:
This situation may relate to the following factors:
1) The voltage of electric power network changes;
2) Serious interference from electric power network or other electric facilities.
D. Gas vent in welds:
1) Examine whether the gas supply circuit has leakage.
2) Examine whether there is sundries such as oil, dirt, rust, paint etc. on the surface.
Summary of Contents for MIG175GD
Page 1: ...USER MANUAL MIG175GD...
Page 2: ......
Page 14: ...USER MANUAL 12 YF 74L A2 Explanatory drawing for Installation of MIG 175GD MIG...
Page 15: ...USER MANUAL 13 YF 74L A2 Explanatory drawing for Installation of MIG 175GD LIFT TIG...
Page 16: ...USER MANUAL 14 YF 74L A2 Explanatory drawing for Installation of MIG 175GD STICK...
Page 27: ...USER MANUAL 25 YF 74L A2 STRUCTURE CHART AND MAJOR PARTS LIST Structure Chart of MIG175GD...