* Notes:

The 

TENSMATE unit is very safe, the output intensity increases only by the “+” key . Even if the intensity is increased to 

the maximum level, it is within the safe range. When user switches the mode, the intensity will automatically go down 
to the minimum level. 

Electrode guidelines:

            Use only the electrodes supplied by the manufacturer, other electrodes may present a risk of unsuitable 
            electrical characteristics with your stimulator.
            Do not use the electrodes on different people. Each user must have their own set, otherwise, skin reaction or 
            cross contamination may occur.
            Always turn power off before removing or repositioning the electrode. 

              Wash skin thoroughly, and then dry it before applying the electrodes.

            Apply the whole surface of the electrodes firmly to the skin. Do not use electrodes that do not stick properly 
            to the skin or only partially stick to the skin. 

            In case of skin redness under the electrodes after a stimulation session, do not start a new session in the same 
            place if skin redness is still evident.    

                                                                        

Directions for use:

Three key points for operation:

1. 

Find the exact pain point:

 The points which the electrode pads are attached to should be the most painful in 

normal time.
2. 

Intensity

: The intensity must be gradually increased, and it’s better to reach the highest intensity you can stand.

3. 

Application duration:

 2-3 times/day, 40-60 minutes/time, over 10 days for one course.

                

TENSMATE unit will come fully charged for first use. 

 

Connect the wire to the output port at  the bottom of the unit. 

                Connect the pads to the wire by snapping them on. 

                

Remove the protective film and place the pads on a muscle making sure that 

both pads are on the skin 

                 and 

not overlapping

.

                 

Turn on the unit via the on/off switch located on the top of the unit.

 

When you have turned on the unit, it will automatically start in mode 1. 

                          To change the modes press the M button. 
                 Once you have selected a mode, gradually increase the intensity by pressing the + button; to decrease 
                  the intensity, press the – button. 
                          To set the time of use, press the T button. 
                 Sit back and enjoy the deep soothing sensations!

Summary of Contents for TENS+EMS

Page 1: ...User manual EN...

Page 2: ...recommendations 10 Maintenance and care 11 Storage conditions 11 Technical specifications 12 Indications of use 13 Unique benefits 14 Regular application principles 15 Regular application methods 15...

Page 3: ...to relieve minor muscular aches and pains It comprises of two main components an electronic stimulatory module which generates the required stimulation signals and 2 sets of pro neo neonatal ECG elect...

Page 4: ...ls use to ease foot and ankle pain It will make your feet feel rejuvenated and pain free The items above are not included in the package They are available at your local distributor Silver thread cond...

Page 5: ...er the battery will charge in either one of the power positions ON or OFF 3 The battery should be charged for 8 10 hours before first use Features FDA approved Class II Medical Device Adjustable timer...

Page 6: ...n session do not start a new session in the same place if skin redness is still evident Directions for use Three key points for operation 1 Find the exact pain point The points which the electrode pad...

Page 7: ...s and rub them on both pads This will help the electrodes maintain their adhesiveness When you finish using the device turn it off Take off the electrode pads Place the protective films back on the el...

Page 8: ...u can use it as often as needed Extremely effective The advanced microchip sends out multiple preset electrical therapeutic electronic waves through the electrodes These therapeutic electronic waves u...

Page 9: ...chinese medicine TCM the most sensible pressure pain point is the key point the most proper position to be applied Find the pressure pain point with reference to Fig 1 Apply one pad onto it Apply the...

Page 10: ...times a day Pain in the muscles and tendons of the limbs it is often caused by sport injury overstrain or some other factors The common signs are muscular pain swelling and spasm Position of electrode...

Page 11: ...ns aresecure fromtheunittothewires and the wires to the pads Increase the intensity level Adhesive electrode pads do not stick to skin even after cleaning and moistening their surface Adhesive gel pad...

Page 12: ...ased Do not attempt to use TENSMATE unit for muscle reeducation to prevent muscle atrophy or spasms improving range of motion blood flow deficiencies venous thrombosis Warnings Stimulation should not...

Page 13: ...e device in the bath or shower Persons with suspected heart problems or epilepsy should obtain apposite medical advice Never use the TENSMATE unit while sleeping Never immerse the TENSMATE unit in any...

Page 14: ...that is new or which has been manufactured from new or serviceable used parts To register your product warranty please visit www hidow com click on the warranties menu and select the warranty that re...

Reviews: