TENSITRON WX-1 Series Operating Instructions Manual Download Page 15

WX-1 Series Instrument     Revised: 10.3.19     

www.tensitron.com          

pg. 15

 

5. 

ENTER WEIGHT

. After selecting the number of calibration points, you need to 

define these weight values. Using the up or down arrows select your first tension, 
or weight calibration point and press 

ENTER. Do not use 0 (zero) as this value is 

already programmed into the instrument

. Next, use the up or down arrows to select 

your 

weight 2 

value, making sure the value entered is greater than the entry in 

weight 1

. Next, select increasing weight values for the additional weight points, 

without exceeding the maximum tension range of the instrument. 
 
6. 

CALIBRATE TENSION

. Next you will calibrate the instrument using the weight 

values you previously selected. To properly simulate these tensions, suspend a 
single length of your web from above and suspend known weights onto the web in 
the values you’ve previously selected, when prompted. (See Figure 7.) 

a.  CALIBRATE TENSION, NUMBER OF POINTS __, ZERO UNIT. 

Without any web engaged to the instrument, hold it in the attitude 
you will be taking the reading in and press ENTER to calibrate 
zero weight. Next the display will prompt you to suspend the 
weight value you previously selected in step 5. If, for example 
you selected 50 lb. for your first weight value the instrument will 
indicate:  PLACE WEIGHT 50. 

b.  Suspend the exact weight value from your web that 

you’ve 

previously selected (In this example it would be 50 lb.) 

c. 

Next, engage the instrument to your tensioned web, then press 
ENTER once the reading has stabilized. 

d.  Repeat steps b. and c. for the remaining weight points by 

suspending additional weights onto your web in the values 
previously selected and entering these readings. 

e.  Once the last weight value is entered, the instrument will return 

to the SETUP menu. Press the ESCAPE button to return to the 
main display. 

f. 

The main display will now indicate the web/material description 
you just finished calibrating. If the material name on the display 
is not the material you just recalibrated, you have re-
programmed the incorrect description. If this happens, you will 
need to recalibrate both the material indicated on the display 
along with the material you thought you were calibrating.  

g.  After completing a calibration always recheck the values. Refer 

to “Check Accuracy” in Section 7. 

Summary of Contents for WX-1 Series

Page 1: ...Operating Instructions WX 1 Series Digital Web Tension Meter...

Page 2: ...all Instruments 6 5 BASIC OPERATION 7 Charging Instrument Batteries 7 Quick Start Instructions 8 Engaging Instrument onto Web 9 6 DISPLAY SCREENS 10 SETUP Screen 10 o LCD Refresh Rate 10 o Data Averag...

Page 3: ...or need assistance please call us at 303 702 1980 or find us online at www tensitron com 1 WARRANTY POLICY STANDARD EQUIPMENT WARRANTY Tensitron warrants that all Tensitron manufactured equipment wil...

Page 4: ...configurations Battery Battery Rechargeable NiMH custom proprietary design Battery lasts approximately 8 hours between charges depending on backlighting intensity Operating Temperature Recommended op...

Page 5: ...proper mountings broken parts and any other condition that may affect operation Do not use a damaged instrument Tag damaged instrument DO NOT USE until repaired For repair send instruments directly to...

Page 6: ...ts can be configured with either of these options o A Analog Output option Data output at 40 Hz 0 5 VDC or 4 20 mA with Software definable ending sequences Provided with 10 web to interface with your...

Page 7: ...IC OPERATION Charging Instrument Batteries 1 Use only a Tensitron power supply to avoid damage to instrument 2 Connect power supply to the instrument Plug the power supply into a power source with inp...

Page 8: ...a displayed on the Main Screen by pressing and holding the STORE button or power the instrument off c For additional information on logging and viewing data refer to Sec 6 Display Screens Data Logging...

Page 9: ...trument to Tensitron and ask to have it added to the menu 7 Zero Instrument Hold the instrument in the attitude your reading will be taken before you engage it to the tensioned web Then press ZERO Eng...

Page 10: ...s Examples The meter takes 300 readings per second so if a 1 second duration is selected the meter will average all 300 readings before posting the average of those readings to the display Likewise if...

Page 11: ...HT and press ENTER Select Low Medium or Full intensity and press ENTER o Set Point Menu This feature displays tension as a colored bar on the main display The colored bar advances as tension increases...

Page 12: ...ress ENTER Use the Up and Down arrows to select Kilograms DecaNewtons or Pounds and press ENTER SELECT MATERIAL Screen Press ENTER while this display is shown to show the available options for the mat...

Page 13: ...ic instrument model listed in Section 4 once properly engaged to the web This procedure confirms the instrument s accuracy and it is now ready for use Note Accuracy Specification NOTE ACCURACY IS MODE...

Page 14: ...icates SETUP RE CALIBRATE TENSION with a list of the calibration names and custom names programmed into the instrument Scroll to the description you wish to recalibrate highlight it and then press ENT...

Page 15: ...reading in and press ENTER to calibrate zero weight Next the display will prompt you to suspend the weight value you previously selected in step 5 If for example you selected 50 lb for your first wei...

Page 16: ...733 S Bowen Street Longmont CO 80501 USA Phone 303 702 1980 Fax 303 702 1982 E mail sales tensitron com Web Site www tensitron com...

Reviews: