background image

11

11

11

10

10

9

9

9

8

8

8

7

6

6

5

4

44

3

3

2

2

2

2

1

1 - Connections Diagrams:

18 - Technicial Specifications:

19 - Index:

20 - Contact:

15 - Demand Time Set:

17 - Dimensions:

13 - Changing Password:
14 - Password Enable/Disable:

11.4 - About the Device:

12 - Enter Menu with Password:

11.3 - RS485 Communication Settings:

11.2 - General Ayarlar:

11.1 - Setup Settings:

11- Menu Structure

 10 - To advance in Display Inventory:

8 - Start-up of the Device:
9 - Display Information:

6 - Introduction of Home Screen:

7 - Definition of Buttons:

2 - Points to take into consideration in the selection 

      

and connection of Current Transformer:

3 - Warnings:

5 - General:

4 - Maintenance of the Device:

Page

Subject:

16 - Parameters Table:

19 - Index:

20 - Contact

-11-

18 - Technicial Specifications:

85V - 240V AC

50 / 60 Hz

<

10VA

-20

ºC

.....55

ºC

5V -300V AC

5V - 300kV

50mA - 5,5A

50mA - 10.000A

%

±

1

3P4W

1....2000

1....999

Plug-in Connection

1.5mm

²

 

Front panel mounted

<

2000meters

<

300Gr.

IP41(Panel), IP20(Body)

91mm x 91mm

Operating Frequency

Operating Power

Operating Temperature

Voltage Input

Voltage Meas. Range

Current Input

Current Meas. Range

Voltage, Current Accuracy

Supported Connection

Current Transformer Ratio

Voltage Transformer Ratio

Connection Type

Operating Voltage

Cable Diameter
Mounting

Operating Altitude

Weight

Protection Class

Panel Hole Sizes

RS485 MODBUS RTU

Communication

71.5 x 61.5

mm 

Glass

 LCD

Display

Muratpaşa Mah. Uluyol Cad. 

İşkent Sanayii Sitesi, E Blok, 1. Kat,

BAYRAMPAŞA / İSTANBUL / TÜRKİYE

Tel: 0212 578 04 38 - 48 Fax: 0212 578 04 36         

Web: 

 Mail: [email protected]

www.tense.com.tr

Energy and 

Compensation 

Tracking System

www.tenseenerji.com

Summary of Contents for EM-07E

Page 1: ...31 I1 I2 I3 S1 S2 S3 F1 F2 F3 It shows the minimum maximum and average values of V1 V2 V3 V12 V23 V31 F1 F2 F3 It shows the minimum maximum average and demand values of I1 I2 I3 S1 S2 S3 You can delet...

Page 2: ...on type 3 phase current and 3 phase voltage and neutral N L1 L2 L3 Load A1 A2 85 240VAC 50 60Hz 6VA B GND A RS485 k3 k2 k1 Curent Transformer Connections l3 l2 l1 CT1 P1 S1 P2 S2 CT2 P1 S1 P2 S2 CT3 P...

Page 3: ...gether with the device Place the switch or circuit breaker close to the device or in a location that is easily accessible for the operator Be sure that the panel to which the device is mounted does no...

Page 4: ...tate of Measurement To navigate from a deep measurement values to another min max avg dmd State of Menu To navigate from menu parameters to another State of changing parameter Decrease value of parame...

Page 5: ...s the Down button Figure 8 It shows the phase phase minimum voltage values The figure 9 is displayed when you press the Down button Figure 9 It shows the phase phase maximum voltage values The figure...

Page 6: ...displayed when you press the Down button Figure 19 It shows the apparent power demand values of each phase The figure 20 is displayed when you press the Down button Figure 16 L1 L2 L3 S kVA kVA kVA Fi...

Page 7: ...ion number You can use ESC button for exit menu 11 Menu Structure Figure 28 Figure 24 Set Figure 25 Figure 26 Figure 27 11 1 Setup Settings Pr 1 Current Transformer Ratio Pr 2 Voltage Transformer Rati...

Page 8: ...cut off device energy min max average and demand values are deleted Press Menu button and enter password to enter program list The figure 25 Setup Settings is displayed when you enter password and pre...

Page 9: ...ate Determines Modbus communication speed Default 9600bps Min 1200bps Max 38400bps Figure 27 ekil 37 Figure 36 Esc Set Figure 36 Figure 37 11 4 About the Device Press Menu button and enter password to...

Page 10: ...e General SET Step 2 Pr 1 is displayed when you press the SET button and press Up button You will see Pr 7 It is using for enable disable password protection It is deleted from screen when you press t...

Page 11: ...3 Pr 10 Pr 11 Pr 1 Pr 2 Password Change Password Protection Demand Time Demand Delete C T Cable Turn Number Serial Number Version Current Transformer Ratio Voltage Transformer Ratio Pr 8 Pr 9 ModBus...

Page 12: ...20 Contact 11 18 Technicial Specifications 85V 240V AC 50 60 Hz 10VA 20 C 55 C 5V 300V AC 5V 300kV 50mA 5 5A 50mA 10 000A 1 3P4W 1 2000 1 999 Plug in Connection 1 5mm Front panel mounted 2000meters 30...

Reviews: