being marked with a crossed-out wheelie 

bin symbol, as depicted below.  

To comply with the Directive, you can 

return your old electro-therapy unit to us 

for disposal. Simply print a postage-paid 

PACKETPOST RETURNS label from our 

website www.tenscare.co.uk, attach this 

to an envelope or padded bag with the 

unit enclosed, and post it back to us. 

Upon receipt, we will process your old 

device for components recovery and 

recycling to help conserve the world’s 

resources and minimise adverse effects 

on the environment. 

 

 

 

 

10.

 

ACCESSORIES 

Expected Service Life 

 

The machine will often last for more 

than 5 years but  is warrantied for 2 

years. Accessories (charging cable, 

gel pads, travel case, and mirror) are 

not covered by the warranty. 

 

The number of applications for each 

gel pad will vary depending on the 

user’s skin condition and humidity. 

Replacement  gel pads  and charging 

lead  are available from your supplier or 

distributor (see back cover for contact 

Summary of Contents for mynd

Page 1: ...0...

Page 2: ...pplications in the areas of gentle electrotherapy muscle toning continence management and pain relief during labour Please read these instructions for use carefully and keep them for later use be sure...

Page 3: ...1 CONTROLS 14 5 2 OPERATING INSTRUCTIONS 15 6 SETTING UP AND USING MYND 17 6 1 CHARGING THE BATTERY 17 6 2 PREPARING FOR SESSION 21 6 3 TREATMENT SESSION 23 6 4 AFTER YOUR TREATMENT SESSION 24 7 CLEAN...

Page 4: ...sed Lot Number indicates the manufacturer s batch code so that the batch or lot can be identified Humidity Limitation indicates the humidity limits to which the medical device can be safely exposed Se...

Page 5: ...sistant and should be protected from liquids The first number 2 Protected against access to hazardous parts with a finger and the jointed test finger of 12 mm 80 mm length shall have adequate clearanc...

Page 6: ...age of 8 if supervised by an adult but there is currently no evidence of effectiveness for users under the age of 18 2 CONTRAINDICATIONS WARNINGS CAUTIONS In this manual A Contraindication is used wh...

Page 7: ...ffect body worn monitoring devices Do not use MYND if you have a cardiac pacemaker implanted defibrillator or other implanted metallic or electronic device Such use could cause electric shock burns el...

Page 8: ...ut authorization of the manufacturer Keep away from children under 5 years of age Long cord risk of strangulation in infants Do not use simultaneously with high frequency hospital diagnostic therapeut...

Page 9: ...rritation develops stop using MYND as a small number of users may have an adverse reaction to the gel Trigeminal neuralgia and Ophthalmic shingles make facial nerves hypersensitive so use of MYND coul...

Page 10: ...to repair the device Degraded gel pads can negatively impact performance or cause other problems Keep this device out of the reach of children pets and pests Do not put the lead wire on or wrapped ar...

Page 11: ...he start of treatment you may tense your neck muscles when you are using MYND and this can lead to an aching neck If this happens try resting your head on a pillow during treatment Note Electrode pads...

Page 12: ...elative Humidity of storage 10 C to 60 C 15 to 75 R H Temperature Relative Humidity of transportation 10 C to 60 C 15 to 75 R H Caution There are no user serviceable parts Do not attempt to open or mo...

Page 13: ...aine patients develop Allodynia with their migraine attacks This makes any skin stimulation including MYND feel painful Programme 1 Treatment Maximum intensity across a load resistance of 500 20 mA Pe...

Page 14: ...h the gel pads always make sure they are in good condition and sticky Make sure you clean the forehead before use After use always replace the clear plastic liner on top of the gel pads on the device...

Page 15: ...s 1 x MYND unit 3 x Reusable gel pads 1 x Charging cable 1 x Travel case 1 x Mirror 1 x Instruction manual 1 x Quickstart guide 5 UNIT INFORMATION 5 1 CONTROLS ON OFF PROGRAMME SELECTOR INTENSITY DOWN...

Page 16: ...ll indicate the end of the session the intensity will gradually decrease and the device switches off If you wish to manually turn the unit OFF press and hold the ON OFF button for 3 seconds You will h...

Page 17: ...lleviate any sudden feeling of a surge as each programme gives a different sensation STRENGTH CONTROLS The buttons marked are the strength controls To increase the intensity in steps of 0 5 mA press a...

Page 18: ...this intensity has become tolerated INTENSITY LEDS The unit has 40 levels of strength The strength level will be indicated by the three LEDs on the bottom of the device Each LED gets brighter as the i...

Page 19: ...ket or PC USB port Whilst the battery is charging the central LED light will flash white slowly and repeatedly The device will take approximately 2 2 5 hours to charge When the battery is fully charge...

Page 20: ...fixed inside the device and so device warnings also apply to the battery Failure to follow these instructions could cause the lithium ion battery to leak acid become hot explode or ignite and cause in...

Page 21: ...ace the battery without adequately trained personnel otherwise it will cause danger such as overtemperature fire or explosion Do not position the equipment during charging such that it is difficult to...

Page 22: ...y damp may allow for better adhesion and stimulation from the device Note Do not use make up removal products to clean your forehead as these leave a greasy film on the skin 2 For first use remove one...

Page 23: ...lace the clear plastic liner back in the travel case The blue liner can be disposed of 6 Place the device in the centre of your forehead roughly 1 cm above the eyebrows The gel pads are reusable Howev...

Page 24: ...ld the ON OFF button on the device for 1 second to switch the unit on 2 Select the desired programme Programme 1 will always be the default programme once powering on the device If you wish to change...

Page 25: ...by the outer edges 2 Re apply the clear plastic liner on the gel pads and store the device in the travel case This will help retain the stickiness of the gel When not being used the device must ALWAY...

Page 26: ...an affect this equipment and should be used no closer than 30cm 12 inches to any part of the device Note As indicated in 5 2 1 1 f of IEC 60601 1 2 2014 for ME EQUIPMENT Note For hospital use full EMC...

Page 27: ...your old device for components recovery and recycling to help conserve the world s resources and minimise adverse effects on the environment 10 ACCESSORIES Expected Service Life The machine will ofte...

Page 28: ...to be free from manufacturing defects for 2 years from date of purchase This warranty is void if the product is modified or altered is subject to misuse or abuse damaged in transit lack of responsible...

Page 29: ...acceptable quality If necessary we will provide circuit diagrams component part lists or other information that will assist authorized service personnel to repair the device Before you send your unit...

Page 30: ...of purchase Retailers name Retailers address Retailers postcode Brief description of problem you are experiencing Returns should be sent to TensCare Ltd PainAway House 9 Blenheim Road Longmead Busine...

Page 31: ...l a lot stronger Always return strength to zero or turn the device off before removing the device from the forehead If the above review has failed to resolve your problem or to report unexpected opera...

Page 32: ...IFICATION Waveform Alternated mono phasic rectangular Amplitude across a load resistance of 500 20 mA Peak zero to peak ve in 40 steps 10 Batteries Built in lithium ion battery Model WEL 302025 Manufa...

Page 33: ...eric pressure 700hPa to 1060hPa Battery storage temperature 10 60 1 month 10 45 3 month 10 28 1 year Humidity 45 75 RH Note The electrical specifications are nominal and subject to variation from the...

Page 34: ...ow us TensCare Ltd TensCareLtd TensCare Limited tenscareltd EC Declaration of Conformity TensCare Ltd hereby declare that an examination of the production quality assurance system has been carried out...

Page 35: ......

Page 36: ...35...

Reviews: