TensCare BEAUTYMAX Instructions For Use Manual Download Page 29

28 

 

If battery leakage occurs and comes in 

contact with the skin or eyes, wash 

thoroughly with lots of water  and 

immediately seek medical attention. 

Warning:

  Keep batteries out of the 

reach of children to prevent them from 

swallowing them by mistake. If 

swallowed by child, contact doctor 

immediately.

 

Caution

  NEVER attempt to 

recharge an alkaline battery. 

Risk of explosion.

  

Caution

 Do not mix old, new, 

or different types of batteries as 

this may lead to battery 

leakage or low battery indication. 

 
Disposal:

 Always dispose of batteries 

and device  responsibly according to 

local government guidelines. Do not 

throw batteries onto a fire. Risk of 

explosion. 

 

11.2. CONNECTING LEAD 

WIRES 

Insert the lead wire plug into the base of 

the unit.

 

 

Attaching the electrode pads to the 

lead wire. 
 
 

Push the pin ends firmly into the pigtail 

ends of the electrode pads. 
 

The lead wires may be damaged by 

rough  handling and  should be treated 

with care. 
 

Lead wire colour coding. 

The ends of the lead wires are coloured 

red or black. One of the electrode pads 

should be positioned over the motor 

point (see 8.3.). 
When using the lead splitters, push the 

pin ends of the lead wire firmly into the 

lead splitter input channel. The ends of 

the lead splitters should then be 

inserting into the pigtail ends of the 

electrode pads. 
 

11.3. PREPARING FOR 

SESSION 

1) Before use make sure your skin is 

clean and dry.  

If you are using the 

FACE

 

programmes, clean the skin carefully 

before applying electrode pads, 

removing all makeup, oils and 

creams. Residue from these can 

prevent the electrode pads from 

adhering properly. Use an Aloe Vera 

based cream after treatment to 

soothe any skin irritation. 

2) Place the electrode pads on the skin, 

see section 8. 

3) If you are using your 

Beauty Max

 

while moving, you can attach the unit 

to your belt using the belt clip or hang 

it around your neck using a neck cord 

(not included). For safety, use thread 

or wool that will snap easily if the unit 

snags on something. 

You can safely lean on the electrode 

pads. The sensation might change. 

Summary of Contents for BEAUTYMAX

Page 1: ...0...

Page 2: ...to be treated Press and hold the ON button to switch the device on Regulate the output intensity for each channel Press and hold the OFF button to switch the device off ON Button P Channel 2 UP Channe...

Page 3: ...e applications in the areas of gentle electrotherapy muscle toning continence management and pain relief during labour Please read these instructions for use carefully and keep them for later use be s...

Page 4: ...2 PAD ADVICE 19 8 3 ELECTRODE PLACEMENT 20 9 CONTENT 23 10 UNIT INFORMATION 24 10 1 CONTROLS DISPLAY 24 10 2 OPERATING INSTRUCTIONS 25 11 SETTING UP AND USING THE BEAUTY MAX 27 11 1 INSTALLATION OF B...

Page 5: ...he device can be identified Atmospheric Pressure indicates the atmospheric limits to which the medical device can be safely exposed Manufacturer Symbol Date of Manufacture indicates the date which the...

Page 6: ...ended use Warning Not suitable for use in children without supervision 3 BEAUTY MAX FEATURES Dual Channel Two independent channels with four electrode pads to treat two areas at the same time Channel...

Page 7: ...dy by contracting the selected muscle group It is particularly convenient for areas that are famous for losing their shape and hard to exercise such as the upper arms and the face Successful athletes...

Page 8: ...later stages of pregnancy Stop using immediately if you experience unexpected contractions WARNINGS Do NOT use when driving operating machinery or similar actions needing muscular control Loose electr...

Page 9: ...use by children unable to understand the instructions or persons with cognitive disabilities i e Alzheimer s disease or dementia Caution Keep away from children under 5 years of age Long cord risk of...

Page 10: ...Caution Do not use high intensity settings if electrodes are smaller than 50x50mm Note Electrode pads supplied have no measurable latex content TO KEEP YOUR DEVICE IN GOOD WORKING ORDER OBSERVE THE FO...

Page 11: ...he intermittent Work Rest phase will start For each programme the unit will go through a stimulation phase Work for 0 10 seconds followed by a phase without stimulation Rest for a similar time This is...

Page 12: ...e size For all programmes except FACE PUBIS and RELAX follow the guidelines below to set the intensity level Phase 1 Preparation Turn up the stimulation gradually until you feel an intermittent tingli...

Page 13: ...e pelvis Use 8 pads and splitters 6 LEG Thighs Calves Suitable for people who wish to tone and shape their legs to obtain a thinner silhouette and to enhance general fitness levels 7 BUST Bust Pectora...

Page 14: ...100 Pulse width s 200 300 500 600 360 300 80 Ramp s 5 5 9 1 3 6 5 2 PROGRAMME 3 Side Abdominal Phase 1 2 3 4 5 6 7 Total Time min 5 5 10 8 7 8 2 45 Stimulation s 2 4 8 10 6 4 1 2 Pause s 2 5 4 6 1 4 4...

Page 15: ...Frequency Hz 10 65 100 4 45 8 100 Pulse width s 400 300 260 500 360 500 80 Ramp s 9 5 3 9 6 5 2 PROGRAMME 7 Bust Phase 1 2 3 4 5 6 7 Total Time min 5 5 5 5 5 3 2 30 Stimulation s 3 4 5 1 4 5 2 Pause...

Page 16: ...a non invasive option for helping lift and or tighten the soft tissues of the face improving facial muscle tone and reducing the signs of ageing Recommended use One treatment session daily 5 days wee...

Page 17: ...days ABS BUTTOCKS AND HIPS PROGRAMMES These programmes help improving body toning and body shaping by generating passive muscle contractions in the selected area It may improve your general fitness l...

Page 18: ...d this area ungraceful or even embarrassing Beauty Max helps to tone firm and lift the triceps and the biceps as it allows you to generate contractions in this specific muscle group Recommended use Ge...

Page 19: ...btaining the best results Place two electrode pads over the bulk of the muscle with one electrode over the muscle s motor point The motor point is the area on the skin that is located closest to the m...

Page 20: ...er and replace them in the re sealable plastic bag If the electrode pads dry out then it is best to buy a replacement pack In an emergency it may be possible to restore some of the tackiness of the pa...

Page 21: ...to the placement guidelines below Note The electrode pad needs to be plugged in to the red lead wire connector the refers to the one for the black lead wire connector FACE Pads placement The face elec...

Page 22: ...V Pads placement Lead splitters should be used to allow for 8 electrode pads to be used simultaneously Use channel 2 and a lead splitter to place 4 electrode pads in the same position on the other sid...

Page 23: ...22 LEGS Pads placement Thigh pad placement 1 Thigh pad placement 2 Calves pad placement BUST Pad placement...

Page 24: ...ti purpose muscle stimulator and body toner 2 x Lead wires L CPT 4 x 50x50mm electrode pads E CM5050 4 x 30x50mm face electrode pads E CM3050 4 x 50x100mm electrode pads E CM50100 2 x Lead splitters L...

Page 25: ...ted Channel 2 strength Time remaining Channel 2 strength UP Programme selector Channel 2 strength DOWN Phase Skip Channel 1 strength DOWN Channel 1 strength UP Low Battery Keypad Lock Channel 1 streng...

Page 26: ...ength in steps of 1 mA press and release the top part of the channel buttons CH1 and CH2 The strength levels are shown on the LCD The strength control buttons will not operate until the unit is proper...

Page 27: ...will show when you need to change the batteries The unit will shut down about 2 minutes after this KEYPAD LOCK If you do not press any keys for 30 seconds the keypad will lock so that only the keys m...

Page 28: ...r dim Caution Remove batteries from your Beauty Max if the unit is unlikely to be used for a long period Some types of batteries may leak corrosive fluid Battery Life Batteries should last at least 15...

Page 29: ...eated with care Lead wire colour coding The ends of the lead wires are coloured red or black One of the electrode pads should be positioned over the motor point see 8 3 When using the lead splitters p...

Page 30: ...fortable reduce the intensity 11 5 AFTER YOUR TRAINING SESSION When the timer reaches zero your session is complete and the unit turns off 1 Check that the control unit is OFF If it is not hold down t...

Page 31: ...g to help conserve the world s resources and minimise adverse effects on the environment 15 ACCESSORIES Expected Service Life The machine will often last for more than 5 years but is warrantied for 2...

Page 32: ...tection Act 1987 Our goods come with guarantees that cannot be excluded under the UK consumer Law You are entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality...

Page 33: ...tached to your body correctly Try using the second lead wire Purchase replacement if necessary Lead wires can break at the bend where they leave the machine giving no or intermittent output Sudden cha...

Page 34: ...ontinuous use No special moisture protection Environmental specifications Operating Storage Temperature range 5 to 40 C Humidity 15 to 93 RH non condensing Atmospheric pressure 700hPa to 1060hPa Tempe...

Page 35: ...34 NOTES...

Page 36: ...ESS POSTCODE DAYTIME TELEPHONE E MAIL MODEL DATE OF PURCHASE ATTACH PROOF OF PURCHASE DO NOT SEND IN ELECTRODE PADS RETAILER S NAME RETAILER S ADDRESS RETAILER S POSTCODE BRIEF DESCRIPTION OF PROBLEM...

Page 37: ...w us TensCare Ltd TensCareLtd TensCare Limited tenscareltd EC Declaration of Conformity TensCare Ltd hereby declare that an examination of the production quality assurance system has been carried out...

Page 38: ...37 Distributed by TensCare Ltd 9 Blenheim Road Epsom Surrey KT19 9BE UK Tel 44 0 1372 723434 www tenscare co uk I BEAUTYMX UK Rev 2 1 05 21...

Reviews: