
Main Contactor &
Brake Relay
XX
Propel Forward
XXX
Propel Reverse
XXX
Scrub Brush Motors
XXX
Scrub Head
Pressure Control
XXX
X
**
Vacuum Motor
X
***
XX
FaST Pump
XXX
X
**
X
Conventional
Solenoid Valve
XXX
X
Solution Flow
Control
XXX
X
**
X
Battery Charge
Indicator
XX
Wand Pump
XX
Hour Meter
**
XX
= Input that will ENABLE Output
X
= Input that will DISABLE Output
*
Vacuum Fan and/or Propel will enable the Hour Meter
**
Activated by pressing a combination of buttons on Touch Panel
***
Cycle Vacuum switch OFF/ON for an additional minute of vacuum motor operation
Recovery
Tank
Interlock
Switch (Tan
k
UP)
FaST Switch
(OFF)
Wand
Switch (ON)
Outputs
Supervisor
Lockout
FaST Switch
(ON)
Inputs and the
Outputs they
Control
In
p
uts
Key Switch
(ON)
Charger
Switch
(Charger
plugged in to
machine)
Vacuum
Switch (ON)
Throttle
Input
(Forward or
Reverse)
Emergency
Stop Switch
(Pressed)
One Step
Scrub Button
(ON)
Low Voltage
Interrupt
T5 – Inputs & Outputs Table
64
T5 9002333 REV.0
2
(
11
-07)
E
Summary of Contents for T5
Page 29: ...T5 Wiring Harness Detail Page 2 of 6 T5 9002333 REV 02 11 07 25 B Symbol Key E ...
Page 30: ...T5 Wiring Harness Detail Page 3 of 6 26 T5 9002333 REV 02 11 07 A C CONTINUED Symbol Key E ...
Page 31: ...T5 Wiring Harness Detail Page 4 of 6 T5 9002333 REV 02 11 07 27 C Symbol Key E ...
Page 32: ...T5 Wiring Harness Detail Page 5 of 6 Symbol Key 28 T5 9002333 REV 02 11 07 E ...
Page 33: ...T5 Wiring Harness Detail Page 6 of 6 Symbol Key T5 9002333 REV 02 11 07 29 E ...