TROUBLESHOOTING -- Continued
PROBLEM
CAUSE
SOLUTION
Poor water pickup
Recovery tank is full or excessive foam
buildup
Drain recovery tank
Loose drain hose cap
Tighten cap
Clogged float shut--off screen located in
recovery tank
Clean screen
Clogged squeegee assembly
Clean squeegee assembly
Worn squeegee blades
Replace or rotate squeegee blades
Incorrect Squeegee blade deflection
Adjust Squeegee blade height
Loose vacuum hose connections
Secure hose connections
Clogged vacuum hose
Remove clogged debris
Damaged vacuum hose
Replace vacuum hose
Recovery tank cover not in place
Properly position cover
Damaged recovery tank cover seal
Replace seal
Faulty vacuum motor
Contact Tennant Service 1-800-553-8033
Poor scrubbing
performance
Debris caught in brush
Remove debris
Worn brushes/pads
Replace brushes/pads
Incorrect brush pressure setting
Adjust pressure setting
Wrong brush/pad type.
Use correct brush/pad
Reduced run time
Batteries not fully charged
Fully recharge batteries
Defective batteries
Replace battery
Batteries need maintenance
See BATTERY MAINTENANCE
Faulty battery charger
Repair or replace battery charger
Solution flow and brush
pressure buttons and
FaST system switch are
locked
Supervisor controls are activated (lock-
out feature)
Contact your Supervisor
FaST Model: FaST
System does not operate
or operate correctly
FaST system switch is not turned on
Turn on FaST system switch
FaST--PAK supply hose not connected
Connect supply hose
Clogged FaST--PAK supply hose or con-
nectors
Soak in warm water to unclog
Empty FaST--PAK carton
Replace FaST--PAK carton
Kink in FaST--PAK supply hose
Undo hose kink
Clogged FaST solution system
Contact Tennant Service 1-800-553-8033
Faulty FaST system on/off switch
Contact Tennant Service 1-800-553-8033
Faulty pump
Contact Tennant Service 1-800-553-8033
Clogged solution tank filter
Drain solution tank. remove solution tank
filter, clean and reinstall
Clogged detergent orifice/filter screen
Replace orifice/filter screen
(See FaST SYSTEM MAINTENANCE)
Clogged FaST solution inlet filter
Contact Tennant Service 1-800-553-8033
Faulty control board
Contact Tennant Service 1-800-553-8033
T5 –
Maintenance
(Page 14 of 15)
20
T5 9002333 REV.0
2
(07-06)
M
Summary of Contents for T5
Page 29: ...T5 Wiring Harness Detail Page 2 of 6 T5 9002333 REV 02 11 07 25 B Symbol Key E ...
Page 30: ...T5 Wiring Harness Detail Page 3 of 6 26 T5 9002333 REV 02 11 07 A C CONTINUED Symbol Key E ...
Page 31: ...T5 Wiring Harness Detail Page 4 of 6 T5 9002333 REV 02 11 07 27 C Symbol Key E ...
Page 32: ...T5 Wiring Harness Detail Page 5 of 6 Symbol Key 28 T5 9002333 REV 02 11 07 E ...
Page 33: ...T5 Wiring Harness Detail Page 6 of 6 Symbol Key T5 9002333 REV 02 11 07 29 E ...