![Tennant 5700XPS Operating Instructions Manual Download Page 65](http://html.mh-extra.com/html/tennant/5700xps/5700xps_operating-instructions-manual_1086764065.webp)
MAINTENANCE
63
5700XPS MM402 (9--98)
ES
t
option: The ES
t
filter should be cleaned
daily.
NOTE:
Do not
use steam to clean the tank.
A vacuum fan filter is located in the recovery tank,
for machines serial number 006956 and above.
Remove and clean this filter daily. Clean by
shaking dust or rinsing pleats with low pressure
water. For machines below serial number 006956,
a screen is located in the solution tank.
NOTE: Be sure the vacuum filter is dry before
reinstalling it in the machine.
SOLUTION TANK
The solution tank stores the cleaning solution.
The solution tank does not require regular
maintenance. If deposits form on the bottom of
the tank, rinse the tank with a strong blast of
warm water. The tank can be flushed through the
fill opening and top access hole.
ES
t
option: The solution tank should be drained
and cleaned daily.
The solution tank contains one standard solution
line filter, and one solution line filter for the power
wand option. If the filters become dirty, the
solution flow will be reduced. Check and clean
these filters if necessary.
NOTE:
Do not
use steam to clean the tank.
A vacuum fan screen is located in the solution
tank, for machines below serial number 006956.
Remove and clean this screen daily. For
machines serial number 006956 and above, a
filter is located in the recovery tank.