OPERATION
15
Tennant 3000/3040/3050 (06--03)
TROUBLE SHOOTING
PROBLEM
CAUSE
SOLUTION
Vacuum motor will not operate.
Power switch in off position.
Turn on machine.
Faulty power cord.
Contact Service Center.
Tripped building circuit breaker.
Reset circuit breaker.
Overheated motor.
Let motor cool, determine cause.
Faulty power switch.
Contact Service Center.
Loose wiring.
Contact Service Center.
Poor vacuum suction.
Loose vacuum hose or attachment
tool connection.
Tighten connections.
Clogged vacuum hose or attachment
tool.
Remove clogged debris.
Full vacuum bag.
Empty vacuum bag.
Air leak in hose.
Replace hose.
Clogged secondary filter or foam filter. Remove filters and clean.
Do not
operate machine without filters in place.
Air leak at bag compartment lid.
Replace lid gasket.
Loose bag compartment lid.
Close lid tightly.
SPECIFICATIONS
MODEL
3000/3040/3050
LENGTH
210mm (8.25 in)
WIDTH
190mm (7.5 in)
HEIGHT
600mm (2 ft)
WEIGHT
5.5 Kg (12 lbs)
VACUUM MOTOR
120V, 1.7hp, 2--stage, 10A, 1200W (3040 & 3050)
120V, 1.15hp, 2--stage, 7.5A, 900W (3000)
220V/230V/240V, 1.3kW, 2--stage, 5A, 1150W (3050)
VACUUM BAG CAPACITY
4.75 L (4.3 qts)
POWER CORD LENGTH
15m (50 ft), Gauge--16/3 (120V) (3040 & 3050)
15m (50 ft), Gauge--18/3 (120V) (3000)
15m (50 ft), Gauge--18/3 (220V/230V/240V) (3050)
DECIBEL RATING AT OPERATOR’S EAR,
INDOORS ON CARPET
<75dB(A)