background image

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for TM-730

Page 1: ...Temperature Humidity Meter TM 730 User s Manual Tenmars HB2TM7300001 TENMARS ELECTRONICS CO LTD ...

Page 2: ......

Page 3: ...curacy 2 4 OPERATING INSTRUCTIONS 3 4 4 LCD Display Functions 3 4 5 Instrument description 3 4 6 MODE 3 4 7 CAL C F Button 4 4 8 MAX MIN AVG Button 4 4 9 Data Hold Button 4 4 10 Power Button 5 4 11 Auto Power Off 5 4 12 Enable Disable Auto Power Off 5 5 End of life 5 6 Accessories 5 7 Warning and Precautions 6 8 EMC 6 9 Accessories 7 10 Battery Replacement 7 ...

Page 4: ... Dual display of temperature and humidity C F alternate Simultaneously hold both temperature and humidity readings Simultaneously hold both maximum and minimum and average readings MAX MIN AVG Auto power off DEW POINT and WET BULB temperature measurement 3 SPECIFICATIONS 3 1 General Specifications Display Dual LCD display The maximum value on the primary display is 999 The maximum value on seconda...

Page 5: ...0 C 60 C 95 RH non condensing Storage Temperature and Humidity 10 to 60 C 70 RH non condensing 3 2 Electrical Specification Temperature 25 C Humidity 90 RH Temperature Measurement Range 20 0 C 50 0 C 4 0 F 122 0 F Humidity Measurement Range 1 0 99 RH 3 3 Accuracy Humidity 3 5 for 20 90 5 for 1 19 9 and 90 1 99 Temperature 1 0 1 8 ...

Page 6: ... Data Hold 9 Relative Humidity 10 C Temperature unit 11 DEW POINT 12 WET BULB 13 F Temperture unit 4 5 Instrument description 1 Sensor 2 LCD 3 C F Temperature unit and calibration button 4 DEW POINT WET BULB Temperature button 5 MAX MIN AVG Reading button 6 Data hole button 7 On Off button 4 6 MODE z During normal measurement press MODE button to switch temperatureÎDew pointÎWet bulb in sequence ...

Page 7: ...r F unit 4 8 MAX MIN AVG Button The MAX MIN feature reads and updates the display to show the maximum or minimum or AVG value measured after you press the MAX MIN button Pressing the MAX MIN button for less than 1 second will put the meter into a mode of displaying the maximum minimum average readings Each time the MAX button is pressed the meter will cycle between MAX and MIN and AVG readings Pre...

Page 8: ...tes of inactivity 4 12 Enable Disable Auto Power Off You can disable or enable Auto Power Off by pressing the button more than 2 second the LCD symbol will disappear or enable 5 End of life Caution This symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal 6 Accessories User manual 1 5V battery AAA MN2400 LR03 AM4 2 Carrying case ...

Page 9: ...Cigarette ashes and dust on the humidity sensor can slow down the sensor s response time while causing inaccuracy in measurements Clean up the sensor periodically by simply blowing away the dust particles Do not apply water or other chemical solvent like alcohol when cleaning Do not place the Temperature Humidity Meter inside any liquid to prevent damage to the Thermometer 8 EMC EMC EN61326 1 This...

Page 10: ...propriate precautions to avoid misleading results when making measurements in the presence of electronic interference 9 Accessories User manual 1 5V battery AAA MN2400 LR03 AM4 2 Carrying case 10 Battery Replacement 1 Turn off the meter and slide out the battery cover 2 Remove the low batteries 3 Replace same type batteries 1 5V LR 03 AAA ...

Page 11: ......

Page 12: ...Light meter RF meter Hot wire Anemometer Co meter Anemometer Lan cable tester Co2 meter Solar power meter Radiation meter Clamp meter Multimeter Phase Rotation tester Digital Insulation tester Our products of high quality are selling well all over the world TENMARS ELECTRONICS CO LTD 6F 586 RUI GUANG ROAD NEIHU TAIPEI 114 TAIWAN E mail service tenmars com http www tenmars com ...

Reviews: