background image

 

TM-4100/TM-4100D 

16 

6.8  Manual Data Memory Storing   

Push“

” button, this meter will save the 

current measured result, and REC with a number 
001~200 will appear. 
Manual data memory Storing: 200 data sets.Over 
load Indication: “

OL

”. 

 

   

 

 

 

6.9 Viewing Data Record 

 

  Press and hold “

” first, and then press 

” button together to enable record reading 

function, the LCD will display “M“ ,Press “

” or 

” button to read the next or previous 

records ,Press and hold “

” button first, and 

then press “

” button together to disable the 

this function. 

 

 

Summary of Contents for TM- 4100

Page 1: ...TACHO Meter TM 4100 TM 4100D TENMARS ELECTRONICS CO LTD User s Manual HB2TM4100001 ...

Page 2: ......

Page 3: ...R Button 14 6 7 AVG and Ring call ON OFF Button 15 6 8 Manual Data Memory Storing 16 6 9 Viewing Data Record 16 7 Setup Mode 17 7 1 St1 Automatic Power On off 17 7 2 St2 Auto Power off Time Setting 18 7 3 St3 Record Interval Time Setup 19 7 4 St4 Screen Backlight ON OFF Setting Note 20 7 5 St5 Backlight off Time to Select the Setting 21 7 6 St6 Buzzer Sound ON OFF Note 21 7 7 St7 ft m Unit Convers...

Page 4: ...ators When you receive the reflected signals the RING bright LCD screen locked The buzzer Features Max Min display display hold on average automatic shutdown buzzer backlight Contact measurement and non contact non contact measuring the distance from the 50 500mm allowing in this way would be dangerous to use the case of the measured object Light weight make the instrument easier to handle Low bat...

Page 5: ...nnect the USB Cable The Screen Display USB Stop the Auto Power Off function With AC DC power supply The Screen Display ADP Stop the Auto Power Off function Installation of Contact The Screen Display Reflected red light signal received The Screen Display RING ...

Page 6: ...utton 5 Power Button 6 REC MEM Button 7 UNIT Button 8 RESET CLR Button 9 AVG Buzzer Right 10 fixed tripod screw hole 11 Battery covers 12 Contact adapter mounting nut 13 Contact adapter 14 Fixed screws 15 Contact type X0 1M 16 Contact type shoulder 17 Power Supply DC 9V 18 USB Connecter 19 Analog pulse output port ...

Page 7: ...bol 14 M Memory reading symbol 4 AVG symbol 15 R REC symbol 5 OVER symbol 16 Contactsymbol 6 ADP symbol 17 RING symbol 7 APS Analog pulse output port connector indicate 8 MAX symbol 9 USB symbol 10 Hold symbol 11 Min symbol 18 counts unit 19 r min RPM unit 20 ms r s m min unit 21 Decimal point 22 m s m min yard s yard min unit ...

Page 8: ...mpling period 62 5 ms to 2 s depending on usage conditions Measuring range z Measuring range non contact AVG ON r s 0 5000 1 9999 200 0 1600 0 ms 0 6000 1 9999 200 0 1999 9 z Measuring range contact AVG ON m m 1 500 19 999 200 0 1999 9 ms 0 0250 1 9999 20 00 33 30 Only speed measurement precision required for the above plus 0 5 rdg Display refresh rate Approx 0 5 to10 times sec Functions MAX MIN d...

Page 9: ...0 to 3 3V Active low low level fixed at 300μs Instrument output setting analog output pulse output Continuous operating time Approx 24 hours TM4100 Dimensions Approx 186x70x36 mm L x W x H Mass Approx 200g Accessories 9V alkaline battery 1 Carrying case 1 REFLECTIVE TAPE 1 sheet per piece Ranges and measurement ranges NOTE 1 the lowermost digit is fixed at 0 at speeds of 20 000 r min and over NOTE...

Page 10: ... 2 200 0 to 1999 9 300 0 to 1999 0 200 0 to 1999 9 150 0 to 1999 0 3 2000 to 19999 2000 to 19990 2000 to 19999 2000 to 19990 Rotation speed measurem ent r m 4 20000 to 99990 20000 to 99990 1 0 5000 to 1 9999 0 2500 to 1 9999 2 2 000 to 19 999 5 000 to 19 990 2 000 to 19 999 2 500 to 19 990 3 20 00 to 199 99 20 00 to 199 90 20 00 to 199 99 20 00 to 199 90 Rotational speed measurem ent r s 4 200 0 t...

Page 11: ...ent MODE Range AVG ON AVG OFF 1 1 500 to 19 999 2 20 00 to 199 99 15 00 to 199 90 Circumferential measurement m min 3 200 0 to 1999 9 200 0 to 1999 0 1 0 0250 to 1 9999 0 2500 to 1 9990 2 2 000 to 19 999 2 000 to 19 990 Circumferential measurement m s 3 20 00 to 33 30 20 00 to 33 30 Accuracy AVG ON AVG OFF Up to 9 999 counts 1dgt 10dgt 10 000 counts or more 2dgt 20dgt 20 000 count or more r min mo...

Page 12: ... of High Rotation Objects Detection of reflected light uses modulated light is input for a fixed period of time about 0 2ms or longer a single pulse is detected For this reason if the light pulse generated by the passing reflective tape is less than 0 2ms detection is not possible The range that can be detected with a 12mm square target of reflective tape is indicated below Radius is the distance ...

Page 13: ...nt Procedures If the reflective tape cannot be attached within this detection range increase the area of the reflective tape so that the generated pulse is 0 2ms to higher For measurement of 30 000r min or higher uses the following method ...

Page 14: ...ctive tape so that the generated pulse is 0 2ms to higher 6 1 Battery Loading Remove the battery cover on the back and put a 9V battery inside Battery replacement When the symbol of appears on the LCD display the battery should be replaced with a new one The battery symbol will be displayed on the LCD this symbol is a battery low indicator 6 2 Power Button z Press button to power on z Again Press ...

Page 15: ...ton for more than 2 seconds to turn on or turn off the backlight function Backlight light turns off automatically after 30 seconds 6 4 Units Button Press button to change the unit Possible Units Non contact RPM r minÎ ms Î countsÎ s Contact RPM r minÎmsÎcounts ft sÎft minÎ yard sÎyard minÎr s RPM r min Î ms ÎcountsÎ m sÎm minÎ r s ...

Page 16: ...ue Maximum value lights up Minimun value lights up This function is not available during count measurement the key is disabled 6 6 RESET CLR Button Operation method key input Operation description The current value maximum value minimum value count measured value and circumferential speed value are reset to zero ...

Page 17: ... method key input Operation description The current value maximum value minimum value is reset to zero Note The measured value is also cleared when switching measurement modes and changing the averaging setting Push button to enable or disable AVG mode Press key more 2 seconds to enable or disable the buzzer When the symbol is on the LCD Display which means the buzzer is on ...

Page 18: ...l appear Manual data memory Storing 200 data sets Over load Indication OL 6 9 Viewing Data Record Press and hold first and then press button together to enable record reading function the LCD will display M Press or button to read the next or previous records Press and hold button first and then press button together to disable the this function ...

Page 19: ...shutdown on off setting Set 2 Adjust auto shutdown time setting Set 3 Record time time Points second set Set 4 Screen backlight on off setting Set 5 backlight Seconds and setting Set 6 Buzzer sounds on off setting Set 7 ft and m setting Setting method see the 7 1 7 7 paragraphs 7 1 St1 Automatic Power On off After entering st1 screen then click to switch from to then click button to confirm the ac...

Page 20: ...en click button to confirm the test status LCD screen on the symbol to restore light for automatic shutdown Press key to save and exit 7 2 St2 Auto Power off Time Setting After entering to St2 automatic shutdown time setting function then the LCD screen will display the time st2 and symbols together to adjust minutes Press button or button to enter the value to adjust the duration of the auto powe...

Page 21: ...he settings from the setting mode The auto power off time default setting is 15 minutes 7 3 St3 Record Interval Time Setup Entered into the records of each storage interval st3 time setting By the press button or button to modify the time value of the duration Press button or button to shift the ...

Page 22: ...n Backlight ON OFF Setting Note After entering st4 screen then click to switch from to then click button to confirm the action performed without backlight To reply to st4 backlight ON please follow the steps to cancel without backlight unit select the LCD screen on the symbol then click button to confirm on the implementation of a backlight Auto Power off Time function ...

Page 23: ...r entering st6 screen then click to switch converted to a 5 00 0 30 1 00 1 30 2 00 2 30 3 00 3 30 4 00 4 30 5 00 cycle Select the time you want and then click button to confirm 7 6 St6 Buzzer Sound ON OFF Note After entering st6 screen then click to switch from to then click ...

Page 24: ... Conversion Options Into the ST7 screen displayed on the switch button for the conversion unit the screen displays Press button to confirm the selection unit Such as to be altered in accordance with the above instructions and then operate a return to the original unit ...

Page 25: ...ver z Replace the battery z Install the battery cover Please take out the battery in case of using adapter 9 Safety Precaution For cleaning the instrument use a soft dry cloth Never use a wet cloth solvents or water etc Operation Altitude Up to 2000M Operating Environment Indoors use This instrument has been designed for being used in an environment of pollution degree 2 ...

Page 26: ...sed to generate conduct or consumer electromagnetic energy Be aware that secondary radiators e g reflective objects such as a metallic fence can cause a local amplification of the field Be aware that the field strength in the near vicinity of radiators increases proportionally to the inverse cube of the distance This means that enormous field strengths can result in the immediate vicinity of small...

Page 27: ... generally incorrectly evaluated and tend to be underrated Before using field strength measuring devices you should thus be certain that all field components to be measured lie in the specified frequency range of the measuring device 11 End of life Caution This symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal ...

Page 28: ...ght meter EMF meter UV Light meter RF mete r Hot wire Anemometer CO meter Anemometer Lan cable tester CO2 meter Solar power meter Radiation meter Clamp meter Multimeter Phase Rotation test Digital Insulation tester Our products of high quality are selling well all over the world TENMARS ELECTRONICS CO LTD 6F 586 RUI GUANG ROAD NEIHU TAIPEI 114 TAIWAN E mail service tenmars com Http www tenmars com...

Reviews: