background image

4

Basic Mode of Operation 

• 

This power supply is designed to operate as a constant voltage source or as a 

constant current source. Automatic crossover to either mode of operation occurs 

when the load condition changes as following :  

Constant Voltage (CV), Automatic crossover & Constant Current (CC) 

• 

The power supply functions as a constant voltage source (CV) as long as the 

load current is less than the preset current limiting value. When the load current 

is equal to or greater than the preset current limiting value, the power supply will 

automatically cross over to the constant current mode, voltage will drop, (CC) will 

show on the LCD display panel and it will operate as a constant current source.  

When the load current drops below the preset current limiting value, the supply 

returns to constant voltage (CV) mode. 

 

Set the Output Voltage and Presetting Current Limiting Value (CC) 

• 

Push the control one time to check the preset voltage and current level. Push the 

control again until the decimal place which you want to adjust. The selected decimal 

place will flash. Turn the control to adjust your desired value. 

• 

To check the preset voltage and current level, just turn the controls lightly in any 

direction or just push the controls one time.  

Tracking Output Over Voltage Protection (OVP) 

• 

This is to protect the connected load in the event that the output voltage control 

circuit malfunctions, the maximum output voltage will not exceed 30% of the 

adjusted voltage value at the time of the operation.  

Over Temperature Protection 

• 

When the temperature inside the power supply becomes higher than a pre-

determined value, the output voltage and current of the power supply will 

automatically decrease to zero to prevent damage to power supply. When the 

temperature inside the power supply returns to about 65°C then the power supply 

will automatically return to operation again.

Summary of Contents for 72-8340A

Page 1: ...1 Model 72 8340A 72 8345A and 72 8350A Switch Mode Bench PSU ...

Page 2: ...Avoid touching the exposed metal of the output terminals Do not block or obstruct any cooling vent opening Avoid severe impacts or rough handling that leads to damage Do not discharge static electricity This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given super...

Page 3: ...load requires more voltage and current Increase the voltage or current accordingly until CV appears Ground Connection Depending on the application the power supply output terminals can be grounded in any one of the following grounding conditions Negative ground black negative terminal is shorted with green GND terminal Positive ground red positive terminal is shorted with green GND terminal Floati...

Page 4: ...ge and Presetting Current Limiting Value CC Push the control one time to check the preset voltage and current level Push the control again until the decimal place which you want to adjust The selected decimal place will flash Turn the control to adjust your desired value To check the preset voltage and current level just turn the controls lightly in any direction or just push the controls one time...

Page 5: ...ng Operation Frequency 80KHz to 120KHz Power Factor 0 65 Efficiency at Maximum Power 84 83 81 Volt and Amp Control Type Rotary Encoder Voltmeter and Ammeter Display 4 Digit Voltmeter Accuracy 0 5 5counts for range V 5V 0 5 5counts for range V 10V 0 5 5counts for range V 20V 0 5 3counts for range V 5V 0 5 3counts for range V 10V 0 5 3counts for range V 20V Ammeter Accuracy 0 5 5counts for range I 2...

Page 6: ...ials used Contact your local authority for details of recycling schemes in your area Made in China PR2 9PP Man Rev 1 0 MAINTENANCE Cleaning Use a damp cloth and a small amount of liquid detergent if necessary Never submerse the power supply in liquid or allow any liquid to enter the case Do not use any chemicals abrasives or solvents that could damage the power supply casing Changing the fuse Repl...