background image

5

SPECIFICATIONS

72-8350A

72-8345A

72-8340A

Input Voltage

0 - 130 / 180 - 264Vac 50 / 60Hz~

Full Load Input Current at 230Vac

0.83A 

Output Voltage Adjustable Range

1.0 - 20Vdc

1.0 – 36Vdc

1.0 - 60Vdc

Output Current Adjustable Range

0 - 5A

0 - 3A

0 - 1.6A

Output Current Adjustable Range

Load from 10% to 100% Variation

120mV

50mV

50mV

Line from 180 to 264Vac Variation

20mV

Ripple & Noise in r.m.s.

5mV

8mV

Ripple & Noise (peak to peak)

30mV

50mV

100mV

Current Regulation

Load from 10% to 100% Variation

20mA 

Line from 180 to 264Vac Variation

20mA

Ripple & Noise (peak to peak)

70mA

20mA

20mA

Switching Operation Frequency

80KHz to 120KHz 

Power Factor

0.65 

Efficiency at Maximum Power

84%

83%

81%

Volt and Amp Control Type

Rotary Encoder 

Voltmeter and Ammeter Display

4 Digit

Voltmeter Accuracy

±0.5% +5counts 

for range V≤5V

±0.5% +5counts 

for range V≤10V

±0.5% +5counts 

for range V≤20V

±0.5% +3counts 

for range V>5V

±0.5% +3counts 

for range V>10V

±0.5% +3counts 

for range V>20V

Ammeter Accuracy

±0.5% +5counts 

for range I≤2A

±0.5% +5counts 

for range I≤1A

±0.5% +5counts 

for range I≤0.5A

±0.5% +3counts 

for range I≤2A

±0.5% +3counts 

for range I≤1A

±0.5% +3counts 

for range I≤0.5A

LCD Indication

CC, CV, Amp, Volt, Output ON-OFF 

Protection 

Short Circuit, Overload, Over Temperature, Tracking OVP

Cooling System

Natural Convection

Dimensions in mm (WxHxD)

70 x 150 x 250mm / 2.8 x 6.0 x 9.8in.

Weight in Kg

2Kgs / 4.4Lbs

Summary of Contents for 72-8340A

Page 1: ...1 Model 72 8340A 72 8345A and 72 8350A Switch Mode Bench PSU ...

Page 2: ...Avoid touching the exposed metal of the output terminals Do not block or obstruct any cooling vent opening Avoid severe impacts or rough handling that leads to damage Do not discharge static electricity This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given super...

Page 3: ...load requires more voltage and current Increase the voltage or current accordingly until CV appears Ground Connection Depending on the application the power supply output terminals can be grounded in any one of the following grounding conditions Negative ground black negative terminal is shorted with green GND terminal Positive ground red positive terminal is shorted with green GND terminal Floati...

Page 4: ...ge and Presetting Current Limiting Value CC Push the control one time to check the preset voltage and current level Push the control again until the decimal place which you want to adjust The selected decimal place will flash Turn the control to adjust your desired value To check the preset voltage and current level just turn the controls lightly in any direction or just push the controls one time...

Page 5: ...ng Operation Frequency 80KHz to 120KHz Power Factor 0 65 Efficiency at Maximum Power 84 83 81 Volt and Amp Control Type Rotary Encoder Voltmeter and Ammeter Display 4 Digit Voltmeter Accuracy 0 5 5counts for range V 5V 0 5 5counts for range V 10V 0 5 5counts for range V 20V 0 5 3counts for range V 5V 0 5 3counts for range V 10V 0 5 3counts for range V 20V Ammeter Accuracy 0 5 5counts for range I 2...

Page 6: ...ials used Contact your local authority for details of recycling schemes in your area Made in China PR2 9PP Man Rev 1 0 MAINTENANCE Cleaning Use a damp cloth and a small amount of liquid detergent if necessary Never submerse the power supply in liquid or allow any liquid to enter the case Do not use any chemicals abrasives or solvents that could damage the power supply casing Changing the fuse Repl...

Reviews: